Appendix F
DMA Programming Examples
VME-MXI-2 User Manual
F-12
© National Instruments Corporation
Table F-1. Address Modifier Codes
Code (Hex)
Description
3F
A24 supervisory block transfer
3E
A24 supervisory program access
3D
A24 supervisory data access
3C
A24 supervisory 64-bit block transfer
3B
A24 nonprivileged block transfer
3A
A24 nonprivileged program access
39
A24 nonprivileged data access
38
A24 nonprivileged 64-bit block transfer
37
Reserved
36
Reserved
35
Reserved
34
Reserved
33
Reserved
32
Reserved
31
Reserved
30
Reserved
2F
Reserved
2E
Reserved
2D
A16 supervisory access
2C
Reserved
2B
Reserved
2A
Reserved
29
A16 nonprivileged access
28
Reserved
27
Reserved
26
Reserved
(continues)