5
ACFIN
ACFAIL* In
Setting this bit causes the VME-MXI-2 to route
the ACFAIL* signal from the MXIbus to the
VMEbus. When this bit is clear, ACFAIL* is
ignored on the MXIbus. This bit is cleared by a
hard reset and is not affected by a soft reset.
4
ACFOUT
ACFAIL* Out
Setting this bit causes the VME-MXI-2 to route
the ACFAIL* signal from the VMEbus to the
MXIbus. When this bit is clear, ACFAIL* is
ignored on the VMEbus. You can route
ACFAIL* in both directions simultaneously.
This bit is cleared by a hard reset and is not
affected by a soft reset.
3
SFIN
SYSFAIL* In
Setting this bit causes the VME-MXI-2 to route
the SYSFAIL* signal from the MXIbus to the
VMEbus. When this bit is clear, SYSFAIL* is
ignored on the MXIbus. This bit is cleared by a
hard reset and is not affected by a soft reset.
2
SFOUT
SYSFAIL* Out
Setting this bit causes the VME-MXI-2 to route
the SYSFAIL* signal from the VMEbus to the
MXIbus. When this bit is clear, SYSFAIL* is
ignored on the VMEbus. You can route
SYSFAIL* in both directions simultaneously.
This bit is cleared by a hard reset and is not
affected by a soft reset.
1
SRIN
SYSRESET* In
Setting this bit causes the VME-MXI-2 to route
the SYSRESET* signal from the MXIbus to the
VMEbus. When this bit is clear, SYSRESET* is
ignored on the MXIbus. This bit is cleared by a
hard reset and is not affected by a soft reset.