Chapter 5
Developing Your Application
©
National Instruments Corporation
5-5
Analog Input»General
Properties»Filter»Analog
Lowpass»Enable
AI.Lowpass.Enable
Enables the lowpass
filter of the channel.
Analog Input»General
Properties»Filter»Analog
Lowpass»Cutoff Frequency
AI.Lowpass.CutoffFreq
Specifies in hertz the
frequency corresponding
to the –3 dB cutoff of the
filter. You can specify
10, 100, 1000, or 10000.
Analog Input»General
Properties»Signal
Conditioning»Bridge»
Configuration
AI.Bridge.Cfg
Specifies whether the
sensor is a type of
Wheatstone bridge.
Analog Input»General
Properties»Signal
Conditioning»Bridge»Shunt
Cal»Shunt Cal Enable
AI.Bridge.ShuntCal.Enable
Specifies whether to
place the shunt
calibration resistor
across one arm of the
bridge.
Analog Input»General
Properties»Signal
Conditioning»Excitation»
Value
AI.Excit.Val
Specifies the amount of
excitation in volts.
Analog Input»Strain»Strain
Gage»Configuration
AI.StrainGage.Cfg
Specifies the
strain-gauge
configuration type.
Analog Input»General
Properties»Signal
Conditioning»Bridge»
Nominal Resistance
AI.Bridge.NomResistance
Specifies in ohms the
resistance of the bridge
in an unloaded condition.
Analog Input»Strain»Strain
Gage»Gage Factor
AI.StrainGage.GageFactor
Specifies the sensitivity
of the strain gauge.
Analog Input»Strain»Strain
Gage»Poisson Ration
AI.StrainGage.PoissonRatio
Specifies the ratio of
lateral strain to axial
strain in the specimen
material.
Table 5-1.
NI-DAQmx Properties (Continued)
Property
Short Name
Description