Appendix B
Timing Signal Information
NI PXI-4220 User Manual
B-10
ni.com
Note
The polarity of AI HOLD COMPLETE is not software selectable when
programmed using NI-DAQmx. It is a positive polarity pulse.
Figure B-12.
AI HOLD COMPLETE Signal Timing
t
w
= 400 to 500 ns
t
d
= 50 to 100 ns
AI CONV CLK
AI HOLD COMPLETE
t
d
t
w