Register Bit Descriptions
Chapter 4
GPIB-1014 User Manual
4-8
© National Instruments Corporation
Command/Data Out Register (CDOR)
VMEbus Address:
Base A 111 (hex)
Attributes:
Write Only, Internal to TLC
7
6
5
4
3
2
1
0
CDO7
CDO6
CDO5
CDO4
CDO3
CDO2
CDO1
CDO0
The Command/Data Out Register (CDOR) is used to move data from the VMEbus to the GPIB
when the interface (TLC) is the GPIB Talker or the Active Controller. Outgoing data is
separately latched by this register and is not destroyed by a read from the DIR. When a byte is
written to the CDOR, the TLC GPIB Source Handshake (SH) function is initiated and the byte is
transferred to the GPIB.
Bit
Mnemonic
Description
7-0w
CDO[7-0]
Command/Data Out Bits 7 through 0