![National Instruments CompactDAQ cDAQ-9185 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/national-instruments/compactdaq-cdaq-9185/compactdaq-cdaq-9185_user-manual_3403867072.webp)
5-2
|
ni.com
Chapter 5
Digital Input/Output and PFI
Static DIO
Each of the DIO lines can be used as a static DI or DO line. You can use static DIO lines to
monitor or control digital signals on some C Series modules. Each DIO line can be individually
configured as a digital input (DI) or digital output (DO), if the C Series module being used allows
such configuration.
All samples of static DI lines and updates of static DO lines are software-timed.
Digital Input
You can acquire digital waveforms using either parallel or serial digital modules.
The DI waveform acquisition FIFO stores the digital samples. The cDAQ chassis samples the
DIO lines on each rising or falling edge of the DI Sample Clock signal.
Digital Input Triggering Signals
A trigger is a signal that causes an action, such as starting or stopping the acquisition of data.
When you configure a trigger, you must decide how you want to produce the trigger and the
action you want the trigger to cause. The cDAQ chassis supports internal software triggering,
external digital triggering, analog triggering, and internal time triggering.
Three triggers are available: Start Trigger, Reference Trigger, and Pause Trigger. An analog or
digital trigger can initiate these three trigger actions. Time can also initiate the Start Trigger. Up to
two C Series parallel digital input modules can be used in any chassis slot to supply a digital
trigger. To find your module triggering options, refer to the documentation included with your
C Series modules. For more information about using analog modules for triggering, refer to the
Analog Input Triggering Signals
section of Chapter 3,
Analog Input
, and the
Analog Output
Triggering Signals
section of Chapter 4,
Analog Output
.
Refer to the
DI Start Trigger Signal
,
DI Reference Trigger Signal
, and
DI Pause Trigger Signal
sections for more information about the digital input trigger signals.
Digital Input Timing Signals
The cDAQ chassis features the following digital input timing signals:
•
DI Sample Clock Signal
*
•
DI Sample Clock Timebase Signal
•
DI Start Trigger Signal
*
•
DI Reference Trigger Signal
*
•
DI Pause Trigger Signal
*
Signals with an * support digital filtering. Refer to the
PFI Filters
section for more information.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com