North American Clutch & Driveline
Rockford, Illinois
Phone: (800) 383-9204
(815) 282-7960
Fax (815) 282-9160
www.naclutch.com
45
45
Table 18. Quick-reference lubrication chart. Also see information
Main Bearings
All Models SP318AM and SP318SBAM Series (except models with purge plug (71) in the
bottom of the bearing carrier)
Apply 1 cc of grease (one shot from a grease gun) before start-up and then every 8-10 hours
operation thereafter, through the fitting on the bearing carrier (55) or sheave housing.
All Models with grease lubrication and with a purge plug in bottom of bearing carrier:
Some models (bearing housing Configuration B, for example) were designed with a plug (71) at
the bottom of the bearing carrier to help purge the old grease from the cavity when new grease
is added.
Item
Amount
Amount
Notes
Throwout Collars
Main Bearings (Grease)
Operation Shaft
Pilot bearing
(Periodic lube)
Pilot bearings
(Pre-lubricated)
Linkage
1cc
Add 1cc
Plug hole.
1cc
1cc
None required
drop
Every 8 – 10 hrs.
Every 8 – 10 hrs.
3 months/ 100 hrs.
3 months /100 hrs.
500 hrs.
NLGI Grade 2 Grease
NLGI Grade 2 Grease
NLGI Grade 2 Grease
NLGI Grade 2 Grease