Event Information
Manual No. SA67-0049-01
A-21
393
3
Battery Power Low.
Battery power is low.
If this message
occurs without
power failure,
replace the
Battery.
394
4
Battery Power OK.
Battery does not
have enough power
to enable the write
data cache.
None.
395
0
Controller is gone.
System is
disconnecting from
this controller.
The connection to
the controller has
been lost.
None.
396
4
Controller powered
on.
Controller was
removed from the
system. Controller
has been powered
off.
None.
397
4
Controller is online.
New controller has
been installed.
None.
398
0
Controller is gone.
System is
disconnecting from
this controller.
Controller was set
online.
None.
399
3
Controller's partner
is gone, controller is
in failover mode
now.
Controller was set
offline.
If you did not
expect this,
investigate.
403
1
Installation aborted.
Equipment
improperly arranged
while powered off.
Re-establish
proper
arrangement.
404
1
Controller firmware
mismatch.
Replacement
controller with
downlevel firmware
installed.
Reload controller
firmware.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......