Event Information
Manual No. SA67-0049-01
A-7
32
1
Initialization
cancelled.
User cancelled the
operation.
Physical disk
must be
initialized again
or the Physical
disk cannot be
used.
33
1
A physical disk
failed because write
recovery failed.
Write recovery
process failed.
Replace physical
disk and rebuild
it.
34
1
A physical disk
failed because
SCSI bus reset
failed.
SCSI bus reset
failed.
Replace physical
disk and rebuild
it.
35
1
A physical disk
failed because
double check
condition occured.
Double check
condition occurred.
Replace physical
disk and rebuild
it.
36
1
A physical disk
failed because
device is missing.
Access to the
physical disk failed.
Replace physical
disk and rebuild
it.
37
1
A physical disk
failed because of
gross error on SCSI
processor.
Gross error occurred
to the on board SCSI
processor.
Replace physical
disk and rebuild
it.
38
1
A physical disk
failed because of
bad tag from the
device.
The device
responded with an
invalid tag.
Replace physical
disk and rebuild
it.
39
1
A physical disk
failed because
command to the
device timed out.
SCSI command
timed out on the
device.
Replace physical
disk and rebuild
it.
40
1
A physical disk
failed because of
the system reset.
System reset
occured.
Replace physical
disk and rebuild
it.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......