Event Information
Manual No. SA67-0049-01
A-3
11
2
Rebuild stopped
because logical
drive failed.
At least one more
physical device failed
in the array. Bad data
table overflow.
It may not be
possible to
recover from this
error. Contact
your service
representative.
12
1
A physical disk has
failed.
A physical disk failed.
A user action caused
the physical disk to
fail.
Replace the
physical disk.
13
4
A new physical disk
has been found.
A physical disk has
been powered on. A
new physical disk
has been added.
Controller was
powered on.
Controller was
added. System has
rebooted.
None.
14
4
A physical disk has
been removed
User removed an
unconfigured
physical disk. An
unconfigured
physical disk failed. A
controller was
removed. A controller
powered off.
Replace the
device if needed.
15
4
A previously
configured physical
disk is now
available.
User set the physical
device to
unconfigured.
None.
16
4
Expand Capacity
Started.
User started the
RAID Expansion
operation. A
suspended RAID
Expansion operation
was started.
None.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......