Overview
A-10
GAM Client User’s Guide
62
4
Hot spare replaced
with a smaller
capacity physical
disk.
The new hot spare
may have a smaller
physical capacity
than the physical disk
it replaced.
The controller's
coercion setting may
have reduced the
configurable size of
the new hot spare.
None.
63
3
A storage access
path has come
online.
PathPilot reported an
access path has
become available.
Storage previously
unavailable has
become available
again.
None. This
indicates that
storage access
has been
restored.
64
3
A storage access
path has been lost.
PathPilot is unable to
access certain
storage on any path.
Storage previously
available is now
unavailable.
Investigate
possible causes;
e.g., cabling,
controller or HBA
failure.
65
3
A storage access
path has shifted to
the alternate path.
PathPilot is unable to
access storage on
the original path but
is able to use the
alternate path.
A PathPilot failover
has occurred.
Investigate
possible causes;
e.g., cabling,
controller or HBA
failure.
66
0
A storage access
path has shifted to
the primary path.
PathPilot is again
able to access
certain storage on
the original path.
A PathPilot failback
has occurred.
None. This
indicates that the
primary path has
been restored.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......