Event Information
Manual No. SA67-0049-01
A-9
48
1
A Physical disk
failed because write
operation of the
'Configuration On
Disk' failed.
Bad Physical disk.
Device write
protected.
Replace
Physical disk
and rebuild it.
Check the
startup option
parameters on
the system.
49
1
A Physical disk
failed because write
operation of 'Bad
Data Table' failed.
Bad Physical disk.
Device write
protected.
Replace
Physical disk
and rebuild it.
Check the
startup option
parameters on
the system.
57
1
Physical disk
missing on startup.
Physical disk
missing.
Replace the
Physical disk or
power-on all
enclosures.
58
3
Rebuild startup
failed due to lower
disk capacity.
Device capacity not
sufficient for doing
rebuild.
Replace with a
disk having
sufficient
capacity.
59
3
Physical disk is
switching from a
channel to the other
channel.
Physical disk
removed or channel
failed
Check FC loop;
replace physical
disk if
necessary.
60
2
Temporary-Dead
physical drive is
automatically made
online.
Temporary-Dead
state caused
because of transient
errors
Analyze event
log to find out
why the drive
was marked
DEAD.
61
4
A standby rebuild
has started.
A physical device
failed and spare was
available.
None.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......