Event Information
Manual No. SA67-0049-01
A-15
158
1
Attempt to read
data from block that
is marked in Bad
Data Table.
Attempt to read from
block that is already
marked bad in Bad
Data Table. Potential
data loss.
Restore data
from a back up.
159
2
Data for Disk Block
has been lost due to
Logical Drive
problem.
Data retained in
RAID Cache for a
Write-back Logical
Drive cannot be
stored to the physical
medium because of
Logical Drive
problem. The Logical
Drive problem could
be because of
multiple physical
medium error or
multiple physical
devices offline or
other reasons.
Insure that all the
Physical Drives
related to the
Logical Drive,
disk channel,
enclosure or
cabling are
functional and
accessible.
Repair or
replace them if
necessary.
160
2
Temporary-Offline
RAID5/RAID3 array
is available to the
user again with the
possibility of data
loss in the array.
Temporary-Offline
state caused
because of transient
errors in physical
drives.
Verify data from
backup.
161
2
Temporary-Offline
RAID0+1/RAID1/
RAID0/JBOD array
is available to the
user again.
Temporary-Offline
state caused
because of transient
errors in physical
drives.
No action.
162
4
An standby rebuild
has started on
logical drive.
A physical disk failed
and a spare device
was available.
None.
256
1
Fan Failure.
Cable connection is
broken. Fan failure.
Replace fan.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......