Event Information
Manual No. SA67-0049-01
A-11
128
4
Consistency check
is started.
User started a
consistency check.
Raidbld started
consistency check.
None.
129
4
Consistency check
is finished.
Consistency check
completed
successfully without
detecting any errors.
None.
130
3
Consistency check
is cancelled.
User cancelled the
consistency check.
Restart
consistency
check, if
required.
131
2
Consistency check
on logical drive
error.
Inconsistent data
was found. Bad
sectors were found.
A physical device
reliability problem.
See bad block
and request
sense table for
more
information.
132
2
Consistency check
on logical drive
failed.
A logical device
became critical. A
logical device failed.
See request
sense data for
more
information.
133
1
Consistency check
failed due to
physical disk failure.
A physical disk failed.
See request
sense data for
more
information.
134
1
Logical drive has
been made offline.
One/multiple
physical device(s)
failed.
It may not be
possible to
recover from this
error. Contact
your service
representative.
135
2
Logical drive is
critical.
One physical device
failed.
Replace the
physical device.
Start the rebuild,
if required.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......