Overview
A-6
GAM Client User’s Guide
26
4
Active spare found.
Device was
configured. Manual
active spare was
done. Automatic
active spare was
done.
None.
27
4
Warm spare found.
Device was
configured. Manual
warm spare was
done. Automatic
warm spare was
done.
None.
28
2
Request Sense
Data available.
A physical device
reported an error.
Firmware reported
an operational error.
Read the
request sense
data to
understand the
root cause.
29
4
Initialization started.
Host started the
initialization.
Wait till the
initialization is
completed. If the
system is
shutdown prior
to this process
being completed
the physical
device can be
made useful only
by reinitializing it.
30
4
Initialization
completed.
Physical device
initialization
completed
successfully.
None
31
3
Initialization failed.
Physical device
could have some
problems with
supporting the SCSI
format command.
Try to initialize
again. Contact
your service
representative.
Table A-2. GAM Events for PCI Controllers
ID
Severity
Description
Details
Actions
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......