MP SERIES™ Battery Backup System
for Traffic Signals: MP2000E System
Volume One: Operating Manual
Page 6-97
The Controller Setup screen appears after the login. The fields in this screen are detailed in
Figure 6-90. See Figure 6-92 controller setup screen shot.
FIELD
DETAILS
IP Address
Subnet Mask
Default Gateway
If not using DHCP, enter data into these fields
Network Link
Speed
The Network link speed is set through a pull-down menu. It is typically
set to “auto” although other available values are:
•
10 full-duplex
•
100 full-duplex
•
10 half-duplex
•
100 half-duplex
DHCP Client
If you have manually entered IP address data, choose “disable” from the
pulldown menu in this field.
Socket Port of
HTTP Setup
This is the IP socket port number. Port 80 is the standard ( TCP ) socket
port number for hyper text transfer protocol ( HTTP ). Other values are
“81” and “disabled.”
Socket Port of
Serial I / O
The Default is 100 — make the number correspond to the terminal
emulator ( HyperTerminal ) serial I / O setting or Myers Emergency Power
Systems MEMS serial I / O setting. Configure the card for TCP server.
Destination IP
Address / Socket
Port ( TCP Client
and UDP )
Connection
These settings correspond to the “TCP Client” and “UDP” selection in
“Socket port of serial I/O.”
Refer to the Hyperterminal Example in Figure 6-113.
TCP Socket
Inactive Timeout
( in minutes )
The default is 10 minutes.
Serial I / O
Settings
With the Ethernet-to-serial adapter card installed in the MP2000E, leave
these settings unchanged. These are the RS232 Communication settings
between the Ethernet card and the MP2000E.
Interface of
Serial I / O
Packet Mode of
Serial Input
Setup Password This allows the Controller Setup access password to be changed. The
default is 1111.
Figure 6-90: Controller Setup Screen Fields