MP SERIES™ Battery Backup System for Traffic Signals: MP2000E System
Volume One: Operating Manual
Page 6-18
NUMBER ITEM
LCD SHOWS
DESCRIPTION
6
Boost Event &
Boost Timer
The number of times unit has been in
Boost Mode and the total amount of
time the unit has been in Boost Mode
since the last reset. In the Boost Timer,
each decimal indicates 6 minutes
7
C1 — C6 Status
Indicates the current Status of C1
through C6 programmable contacts.
8
Firmware
Versions
UPS control PCB firmware version and
LCD control PCB firmware version
9
HTML Ethernet
card IP Settings
IP settings for HTML Ethernet card
(only) Ethernet-to-serial card ( or no
card ) shows all zeros
10
Program I/P
Contact & I/P
Contact
Description
Indicates Programmed Value of the
input contact.
11
Program
Contacts
[submenu]
Displays the programming of the 6 front
panel contact closures
12
Line
Conditioning
[submenu]
Allows user to access menu that
displays the Programmed Value of all
input Line Detection parameters and
warning levels
13
Alarms
[submenu]
Allows user to access menu that
displays Alarms. Alarms are described
in Section 6.b.12.
14
Faults
[submenu]
Allows user to access menu that
displays Faults. Faults are described in
Section 6.b.12.
Figure 6-11: Status Submenu (continued)