Rockhopper II series printers – Maintenance Manual
277
AP-74065, Rev. 1.2, 27/09/04
9.2.3. Heating system error
The following explains the messages, items to be confirmed and remedies to take when errors handling
heating system occur while the product is operating.
Heating system errors are displayed when communication trouble occurs between the heater strips and this
product.
If heating system error occurs, the following error messages are displayed and the printer stops.
Solve the problem to delete the error message and restart the printer.
No Message
Check point
Action
1
AC not present
AC connector.
Check AC connector
2
Error sensors A
Sensors A
Check if the sensors are connected properly.
3
Error sensor A
Sensor A
Check if the sensors are connected properly.
4
Conn. err. Left A
Sensor A
Check if the left sensor is connected properly.
5
Conn. err. Right A
Sensor A
Check if the right sensor is connected properly.
6
Error sensors D1
Sensors D1
Check if the sensors are connected properly.
7
Error sensor D1
Sensor D1
Check if the sensors are connected properly.
8
Conn. err. Left D1
Sensor D1
Check if the left sensor is connected properly.
9
Conn. err. Right D1
Sensor D1
Check if the right sensor is connected properly.
10
Error sensors D2
Sensors D2
Check if the sensors are connected properly.
11
Error sensor D2
Sensor D2
Check if the sensors are connected properly.
12
Conn. err. Left D2
Sensor D2
Check if the left sensor is connected properly.
13
Conn. err. Right D2
Sensor D2
Check if the right sensor is connected properly.
14
Couldn't reach temp
Heater strip
After 10 minutes, temperature is not reached. Check
the heater strips.
15
Err: Temp > 85°C!
Heater strip
Temperature comes higher then the limit. Check the
heater strips.
16
Connection err. A
Rear Heater (A)
Check the connector of the rear heater.
17
Connection err. D1
Dryer (D1)
Check the connector of the front heater (D1).
18
Connection err. D2
Dryer (D2)
Check the connector of the front heater (D2).
19
Error sensor B1
Fixer (B1)
Check the sensor of the fixer 1 (B1).
20
Error sensor C
Post fixer (C)
Check the sensor of the fixer (C).
21
Connection err. B1
Fixer (B1)
Check the connector of the fixer 1 (B1).
22
Connection err. C
Post fixer (C)
Check the connector of the post fixer (c).
23
Error sensor B2
Fixer (B2)
Check the sensor of the fixer 2 (B2)
24
Connection err. B2
Fixer (B2)
Check the connector of the fixer 2 (B2).
25
Error D group
Heaters D
Temperature difference higher than 15°C between
the sensors of the D heaters.
26
Error A group
Heaters A
Temperature difference higher then 15°C between
the sensors of the A heaters.
27
Error B group
Heaters B
Temperature difference higher then 15°C between
the sensors of the B heaters.
Important :
Before checking the connectors, please power off the unit and remove the power cable.
Notes :
¾
Check if the connectors are properly connected to the power board.
¾
Check if the sensors are connected onto the right connector.
Содержание Rockhopper II 2H
Страница 1: ...Maintenance Manual MUTOH EUROPE N V AP 74065 Rev 1 2 27 09 2004 ...
Страница 3: ...Rockhopper II series printers Maintenance Manual 4 AP 74065 Rev 1 2 27 09 04 ...
Страница 5: ...Rockhopper II series printers Maintenance Manual 6 AP 74065 Rev 1 2 27 09 04 ...
Страница 7: ...Rockhopper II series printers Maintenance Manual 8 AP 74065 Rev 1 2 27 09 04 ...
Страница 13: ...Rockhopper II series printers Maintenance Manual 14 AP 74065 Rev 1 2 27 09 04 ...
Страница 29: ...Rockhopper II series printers Maintenance Manual 30 AP 74065 Rev 1 2 27 09 04 ...
Страница 201: ...Rockhopper II series printers Maintenance Manual 202 AP 74065 Rev 1 2 27 09 04 ...
Страница 255: ...Rockhopper II series printers Maintenance Manual 256 AP 74065 Rev 1 2 27 09 04 ...
Страница 318: ...Rockhopper II series printers Maintenance Manual 319 AP 74065 Rev 1 2 27 09 04 ...