Section 75
00-02-0878
2013-03-07
- 136 -
Error Log
It is possible to retrieve and acknowledge alarms in the error log of the Scania EMS S6 (KWP
2000).
The alarms available are the same alarms which can be read by the flash combination of the
diagnostics lamp on the EMS S6 (please refer to the engine documentation).
NOTE:
The EMS S6 software version and engine number is automatically
retrieved when CANbus communication is established.
Flash
Code
EMS-GC10
Displayed Text
Description
11
Overreving
One or both engine speed sensors have indicated above 3000 rpm
12
Speed sensor 1
Engine sensor 1
13
Speed sensor 2
Engine sensor 2
14
Water T sen.
Engine coolant temperature sensor
15
Char. air T sen
Charge air temperature sensor
16
Char. air P sen
Charge air pressure sensor
17
Oil temp. sen.
Oil temperature sensor
18
Oil pres. sen.
Oil pressure sensor
23
Fault in cor.
Fault in coordinator
25
Throttle pedal
CAN message for fine tune nominal speed out of range
27
Emerg. stop o.r
Engine stop overridden
31
Oil pres. prot
Oil pressure protection activated
32
Wrong parameter
Wrong parameter setting for defect CAN communication
33
Battery voltage
Battery voltage out of range
37
Emerg. stop cor
Emergency stop switch activated
43
CAN cir. defect
CAN circuit defect
48
CAN mess. DLN1
CAN message from the coordinator missing or not correct
49
Wrong CAN ver.
Non-matching CAN version in EMS and coordinator
51
Un. inj. cyl. 1
Unit injector cylinder 1
52
Un. inj. cyl. 2
Unit injector cylinder 2
53
Un. inj. cyl. 3
Unit injector cylinder 3
54
Un. inj. cyl. 4
Unit injector cylinder 4
55
Un. inj. cyl. 5
Unit injector cylinder 5
56
Un. inj. cyl. 6
Unit injector cylinder 6
57
Un. inj. cyl. 7
Unit injector cylinder 7
58
Un. inj. cyl. 8
Unit injector cylinder 8
59
Extra ana. inp.
Voltage out of range on extra analogue input pin
61
System shutdown
System shut down incorrectly
Содержание EMS-GC10
Страница 1: ...00 02 0878 Section 75 2013 03 07 GensetControllerUnit ModelEMS GC10 Operator sManual ...
Страница 14: ...Section 75 00 02 0878 2013 03 07 8 Menu Structure Diagram ...
Страница 32: ...Section 75 00 02 0878 2013 03 07 26 Mode Shift NOTE To enable mode shift a digital input has to be set up ...
Страница 33: ...Section 75 00 02 0878 2013 03 07 27 MB Open Sequence ...
Страница 34: ...Section 75 00 02 0878 2013 03 07 28 GB Open Sequence ...
Страница 35: ...Section 75 00 02 0878 2013 03 07 29 Stop Sequence ...
Страница 36: ...Section 75 00 02 0878 2013 03 07 30 Start Sequence ...
Страница 37: ...Section 75 00 02 0878 2013 03 07 31 MB Close Sequence ...
Страница 38: ...Section 75 00 02 0878 2013 03 07 32 GB Close Sequence ...
Страница 39: ...Section 75 00 02 0878 2013 03 07 33 Load Takeover LTO ...
Страница 40: ...Section 75 00 02 0878 2013 03 07 34 Island Operation ...
Страница 41: ...Section 75 00 02 0878 2013 03 07 35 Automatic Mains Failure AMF ...
Страница 42: ...Section 75 00 02 0878 2013 03 07 36 Test Sequence ...
Страница 48: ...Section 75 00 02 0878 2013 03 07 42 Stop Sequence The drawings illustrate the stop sequence ...
Страница 74: ...Section 75 00 02 0878 2013 03 07 68 Start ...
Страница 75: ...Section 75 00 02 0878 2013 03 07 69 Stop ...
Страница 183: ...Section 75 00 02 0878 2013 03 07 177 ...