Alignment & Troubleshooting
Service Manual
4-56
Code
Displayed Name
Meaning
State
Displayed
102-0030
T2 Feed Sensor (or Door
Open)
Detect when a paper is at T2 Feed sensor. (optional)
High[low]
102-0031
T3 Feed Sensor (or Door
Open)
Detect when a paper is at T3 Feed sensor. (optional)
High[low]
102-0033
Regi. Sensor
Detect when a paper is at Regi. sensor.
High[low]
102-0034
Exit Sensor
Detect when a paper is at Exit. sensor.
High[low]
102-0035
Duplex Jam1 Sensor
Detect when a paper is at Duplex Jam1 sensor.
High[low]
102-0036
Duplex Jam2 Sensor
Detect when a paper is at Duplex Jam2 sensor.
High[low]
105-0000
Yellow MHV Bias
Yellow MHV bias voltage on at normal drive level
On[Off]
105-0001
Magenta MHV Bias
Magenta MHV bias voltage on at normal drive level
On[Off]
105-0002
Cyan MHV Bias
Cyan MHV bias voltage on at normal drive level
On[Off]
105-0003
Black MHV Bias
Black MHV bias voltage on at normal drive level
On[Off]
105-0004
Yellow MHV Bias Read
Yellow Detect what the MHV value is on the MHV
Roller
On[Off]
105-0005
Magenta MHV Bias Read
Magenta Detect what the MHV value is on the MHV
Roller
On[Off]
105-0006
Cyan MHV Bias Read
Cyan Detect what the MHV value is on the MHV
Roller
On[Off]
105-0007
Black MHV Bias Read
Black Detect what the MHV value is on the MHV
Roller
On[Off]
106-0000
Yellow Dev Bias
Yellow Dev bias voltage on at normal drive level
On[Off]
106-0001
Magenta Dev Bias
Magenta Dev bias voltage on at normal drive level
On[Off]
106-0002
Cyan Dev Bias
Cyan Dev bias voltage on at normal drive level
On[Off]
106-0003
Black Dev Bias
Black Dev bias voltage on at normal drive level
On[Off]
107-0000
Yellow THV Bias Read
Detect what the THV value is on the THV Roller
Numeric 3
digits
107-0001
Magenta THV Bias Read
Detect what the THV value is on the THV Roller
Numeric 3
digits
107-0002
Cyan THV Bias Read
Detect what the THV value is on the THV Roller
Numeric 3
digits
107-0003
Black THV Bias Read
Detect what the THV value is on the THV Roller
Numeric 3
digits
107-0004
iTHV(+) Bias
iTHV plus bias voltage on at normal drive level
On[Off]
107-0005
iTHV Bias Read
Detect what the THV value is on the iTHV Roller
107-0006
iTHV(-) Bias
iTHV minus bias voltage on at normal drive level
On[Off]
109-0000
Fuser Temperature A
Detects what the temperature A is on fuser.
Numeric 3
digits
109-0001
Fuser Temperature B
Detects what the temperature B is on fuser.
Numeric 3
digits
Содержание MFX-C4000
Страница 2: ......
Страница 14: ...Precautions Service Manual 1 6 ...
Страница 35: ...Service Manual 2 21 Video Controller Power Distribution Product Specifications and Features ...
Страница 37: ...Service Manual 2 23 Engine Controller Power Distribution Product Specifications and Features ...
Страница 39: ...Service Manual 2 25 DADF Block Diagram Product Specifications and Features ...
Страница 106: ...Maintenance and Disassembly Service Manual 3 44 ...
Страница 173: ...Alignment Troubleshooting Service Manual 4 67 Diagnostics Test Routines Other Reset Admin password ...
Страница 216: ...Alignment Troubleshooting Service Manual 4 110 ...
Страница 217: ...System Diagram Service Manual 5 1 5 System Diagram 5 1 Block Diagram 5 1 1 System ...
Страница 218: ...System Diagram Service Manual 5 2 5 1 2 Video Controller ...
Страница 219: ...System Diagram Service Manual 5 3 5 1 3 Engin Controller ...
Страница 220: ...System Diagram Service Manual 5 4 5 1 4 OPE Unit ...
Страница 221: ...System Diagram Service Manual 5 5 5 1 5 DADF ...
Страница 222: ...System Diagram Service Manual 5 6 5 1 6 SCF HCF ...
Страница 225: ...System Diagram Service Manual 5 9 5 2 3 OPE Unit ...
Страница 226: ...System Diagram Service Manual 5 10 5 2 4 DADF ...
Страница 227: ...System Diagram Service Manual 5 11 5 2 5 SCF HCF ...
Страница 228: ...System Diagram Service Manual 5 12 ...
Страница 237: ...Reference Information Service Manual 6 9 ...
Страница 238: ...Reference Information Service Manual 6 10 ...
Страница 239: ...Reference Information Service Manual 6 11 ...
Страница 240: ...Reference Information Service Manual 6 12 ...
Страница 273: ...Installation Service Manual 7 31 5 Connect the foreign device interface harness to video controller ...
Страница 279: ......
Страница 280: ...Muratec America Inc 3301 East Plano Parkway Ste 100 Plano Texas 75074 469 429 3300 Tel 469 429 3465 Fax www muratec com ...