![Multitech MT1932ZDX Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/multitech/mt1932zdx/mt1932zdx_quick-reference-manual_1855883035.webp)
35
Chapter 4 - AT Commands, S-Registers and Result Codes
Command:
%E
n
Escape Sequence Options
Values:
n
= 0–5
Defaults:
1 and 4
Description:
%E0
Modem won’t escape.
%E1
+++AT<CR> method.
%E2
<BREAK>AT<CR> method.
%E3
Both +++AT<CR> and <BREAK>AT<CR>
methods.
%E4
No
OK
response to +++AT<CR>.
%E5
OK
response to +++AT<CR>.
Command:
&F
n
Load Default Configurations
Values:
n
= 0, 8, or 9
Default:
8
Description:
&F0
Load factory default values from ROM if &F8 was
previously stored; load user default values from
non-volatile memory if &F9 was previously stored.
&F8
Read factory default values when &F is issued
(effective only if you store &F8 using &W0).
&F9
Read values stored in non-volatile memory when
&F is issued (effective only if you store &F9 using
&W0).
Command:
$F
n
Enable/Disable Auto-Reliable Fallback
Character
Values:
n
= 0 or 1
Default:
0
Description:
$F0
Do not fall back to non-error correction mode
connect if <CR> is received during handshake.
$F1
Fall back to non-error correction mode connect if
<CR> is received during handshake.
Содержание MT1932ZDX
Страница 1: ...Quick Reference Guide...