- 68 -
•
Local Port number (TCP server port number of the reader)
•
Remote IP address (IP address of the connected PC)
•
Remote Port number (Port number of the connected PC)
•
TCP/IP server socket status
?version
•
Local IP address (IP address of the reader)
•
Local Port number (TCP server port number of the reader)
•
System
version
•
Decoder
version
•
Model
name
discon<TCP/IP port number>
Shut down TCP/IP connection of the specified port number.
* <TCP/IP port number> should be set in decimal.
e.g.) discon 27110
The command “?who”, “?netstat”, “?version” and “discon” can be used in UDP/IP
connections.
6.8 Initialize LAN settings
If the LAN settings are unknown, the following steps will reset the LAN settings:
- Turn off power of the reader.
- Turn on power pressing the “Teach” button on membrane switch.
Default settings
IP address
: 192.168.209.xxx
Sub net mask
: /24
Default Gateway
: 192.168.209.254
Port
:
27110