AirWorks AWK-1131A
Web Console Configuration
3-40
Load Factory Default
Use this function to reset the AWK-1131A and rollback all settings to the factory default values. You can also
reset the hardware by pressing the reset button on the top panel of the AWK-1131A.
Account Settings
To ensure that devices located at remote sites are secure from hackers, we recommend setting up a
high-strength password the first time you configure the device.
Field
Description
Default setting
Minimum
password length
By default, passwords can be between 4 and 16 characters. For
improved security, we recommend changing the minimum
password length to at least 8 characters the first time you
configure the device.
4
Password
strength check
Enable the password strength check option to ensure that users
are required to select high-strength passwords.
Disable
Password
validity
The number of days after which the password must be changed.
Passwords should be updated regularly to protect against hackers.
90 days
Password retry
count
The number of consecutive times a user can enter an incorrect
password while logging in before the device’s login function is
locked.
5
Lockout time
The number of seconds the device’s login function will be locked
after n consecutive unsuccessful login attempts, where n = the
password retry count.
600 seconds