AirWorks AWK-1131A
Web Console Configuration
3-26
Protocol
Version
Setting on
UI web page
Authentication
Type
Data
Encryption
Method
SNMP
V1, V2c
V1, V2c
Read
Community
Community string No
Use a community string match for
authentication
V1, V2c
Write/Read
Community
Community string No
Use a community string match for
authentication
SNMP V3 No-Auth
No
No
Use account with admin or user to access
objects
MD5 or SHA
Authentication
based on MD5 or
SHA
No
Provides authentication based on HMAC-MD5,
or HMAC-SHA algorithms. 8-character
passwords are the minimum requirement for
authentication.
MD5 or SHA
Authentication
based on MD5 or
SHA
Data
encryption
key
Provides authentication based on HMAC-MD5
or HMAC-SHA algorithms, and data encryption
key. 8-character passwords and a data
encryption key are the minimum requirements
for authentication and encryption.
The following parameters can be configured on the
SNMP Agent
page. A more detailed explanation of each
parameter is given below the following figure.
SNMP agent
Setting
Description
Factory Default
Enable
Enables SNMP agent
Disable
Disable
Disables SNMP agent
Remote management
Setting
Description
Factory Default
Enable
Allow remote management via SNMP agent
Disable
Disable
Disallow remote management via SNMP agent
Read community (for V1, V2c)
Setting
Description
Factory Default
V1, V2c Read
Community
Use a community string match with a maximum of 31
characters for authentication. This means that the SNMP agent
can access all objects with read-only permissions using this
community string.
public