background image

 

 

 

Manual 

  

 

 

 

758-919  

Wireless Access Point 

  

Version 1.0.0  

 

 

 

Содержание 758-919

Страница 1: ...Manual 758 919 Wireless Access Point Version 1 0 0...

Страница 2: ...upport wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any informatio...

Страница 3: ...tion 16 3 2 View 18 3 3 Labeling 19 3 4 Connectors 20 3 5 RJ45 LED Indicators 21 3 6 RESET Button 22 3 7 Technical Data 23 3 7 1 Hardware Specifications 23 3 7 2 Communication 23 3 8 Approvals 25 3 8...

Страница 4: ...luetooth 50 6 1 3 EtherNet IP Networking via Bluetooth 51 6 1 4 Ethernet network to existing WLAN 52 6 1 5 Adding single Ethernet node to WLAN 53 6 1 6 Accessing PLC via WLAN from Handheld Device 54 6...

Страница 5: ...to this documentation is included if necessary This documentation applies to the Wireless Access Point 758 919 1 1 Copyright This Manual including all figures and illustrations is copyright protected...

Страница 6: ...e risk potentially hazardous situation which if not avoided could result in death or serious injury Personal Injury Indicates a low risk potentially hazardous situation which if not avoided may result...

Страница 7: ...s about this Documentation 7 758 919 Wireless Access Point Manual Version 1 0 0 Additional Information Refers to additional information which is not an integral part of this documentation e g the Inte...

Страница 8: ...rked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item from a menu e g File...

Страница 9: ...ried out by electrical specialists with sufficient knowledge in installation and handling of electrical equipment The electrical specialists must also be familiar with the current standards and guidel...

Страница 10: ...9 Wireless Access Point Manual Version 1 0 0 Further details are given in the contractual agreements Please send your request for modified and new hardware or software configurations directly to WAGO...

Страница 11: ...k of cyber attacks and to enhance cyber security Only open ports and services during commissioning and or configuration Limit physical and electronic access to all automation components to authorized...

Страница 12: ...are to be stored in their original packaging Likewise the original packaging provides optimal protection during transport When assembling or repacking the components the contacts must not be soiled o...

Страница 13: ...ce is only restricted for use in hazardous areas Maintenance Repair only by authorized specialists The device contains no parts that can be serviced by users Always have all service reconfiguration ma...

Страница 14: ...and materials are imperative for handling devices modules Cleaning only with permitted materials Clean soiled contacts using oil free compressed air or with ethyl alcohol and leather cloths Avoid elec...

Страница 15: ...re replacing or wiring modules Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations Install in an enclosure considered representativ...

Страница 16: ...es such as MODBUS TCP EtherNet IP or PROFINET In combination with another function related device e g another WAP or Access Point AP of the same radio technology the WAP can serve as a wireless replac...

Страница 17: ...ementation of Bluetooth by various manufacturers 5 GHz WLAN cannot be used with 2 5 GHz WLAN or Bluetooth at the same time WLAN or Bluetooth Choose WLAN if data throughput and wireless roaming are req...

Страница 18: ...2 View Figure 2 View Table 3 Legend for Figure View Pos Description Details see Section 1 Antenna for WiFi and Bluetooth Technical Data 2 Power Connector Art Nr 2734 103 107 000 3 ETHERNET Connector...

Страница 19: ...vice MAC address is included with other data on the device Figure 3 Marking Type Plate Part 1 Example Figure 4 Marking Type Plate Part 2 Example Table 4 Legend for Figure Label Example No Serial NO De...

Страница 20: ...also Chapter Technical Data regarding power supply requirements Table 5 Power Connector 3 pin terminal block Pin Function 1 19 36 VDC 2 3 Functional Earth FE Table 6 Ethernet Connector RJ45 PoE Pin D...

Страница 21: ...Function Off No power Blue Connected on all configured wireless interfaces Purple Trying to connect to WLAN Bluetooth access point Blue slow blink Awaiting connections Alternating blue purple Connect...

Страница 22: ...Point Manual Version 1 0 0 3 6 RESET Button Figure 7 RESET Button The RESET button is located on the bottom of the unit When the unit is powered on press and hold RESET for 10 seconds and then releas...

Страница 23: ...midity EN 600068 2 78 Damp heat 40 C 93 humidity for 4 days Dimensions Height 75 mm 91 mm with PS connector Outside height 41 mm Diameter 68 mm Weight 84 g Protection class Top outside of host IP66 IP...

Страница 24: ...11n SISO Security WEP 64 128 WPA WPA PSK and WPA2 TKIP and AES CCMP LEAP PEAP including MS CHAP Table 12 Classic Bluetooth Wireless standards profiles PAN PANU NAP Operation modes Access point or Clie...

Страница 25: ...use only 5GHz FCC Federal Communications Commission CFR 47 Part 15 ETS 300328 FCC ID PVH0965 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 t...

Страница 26: ...ired operation This product contains FCC ID PVH0965 Damage to Property Any changes or modifications not explicitly approved by WAGO Kontakttechnik GmbH Co KG could cause the module to cease to comply...

Страница 27: ...e maximum range can only be effective under optimal conditions A lack of line of sight link or mis alignment of the devices will result in reduced range For a line of sight link install the devices su...

Страница 28: ...also possible without line of sight but the range is substantially reduced depending on the obstacle e g a wall A fire protection wall or a steel reinforced concrete ceiling is located between the de...

Страница 29: ...Area Network may not work with some devices due to different implementations of Bluetooth by different manufacturers WLAN 5 GHz cannot be used at the same time as WLAN 2 4 GHz or Bluetooth Do not ins...

Страница 30: ...e using the included sealing ring and nut The top mounting surface in contact with the sealing must be flat with a finish equivalent to Ra 3 2 or finer and cleaned and free from oils and greases Tight...

Страница 31: ...oint The default address is 192 168 0 99 The computer accessing the web interface must be in the same IP subnet as the Wireless Access Point Figure 9 Web interface The device is configured as a WiFi a...

Страница 32: ...for the wired and wireless interfaces The different parameters are explained in the descriptions of each settings page in this manual The Help page describes AT commands that can be used for advanced...

Страница 33: ...ents Apply PROFINET optimization to all units 8 Bluetooth NAP 9 Bluetooth PANU Configure as Bluetooth client and scan for another client PANU PANU Apply PROFINET optimization to both units 10 any Appl...

Страница 34: ...this mode the unit must be restored to factory defaults by pressing and holding the RESET button Modes 10 and 11 will be added to the configuration without changing any other settings Modes 1 and 9 wi...

Страница 35: ...erfaces Only a single DHCP server can be active for all the connected interfaces If WLAN is used the forwarding mode must be set to Layer 3 IP Forward DHCP Server Enabled Activates an internal DHCP se...

Страница 36: ...communicate on one band at a time Scan for Networks Click to scan the selected frequency band s for discoverable WLAN networks Select a network from the dropdown menu to connect to it Connect to SSID...

Страница 37: ...an be permanently disabled using AT commands See the Help page in the web interface for more information about how to set up WLAN roaming WLAN Channels and World Mode Client Mode only Which channels a...

Страница 38: ...136 140 ETSI 1 11 12 13 36 40 44 48 52 56 60 64 100 104 108 112 116 120 124 128 132 136 140 FCC 1 11 36 40 44 48 52 56 60 64 100 104 108 112 116 132 136 140 Notes The maximum output power will be redu...

Страница 39: ...ption mode to use for the access point Open No encryption or authentication WPA2 WPA2 PSK authentication with AES CCMP encryption WPA2 Passkey Enter a string in plain text or hexadecimal format to use...

Страница 40: ...on 758 919 Wireless Access Point Manual Version 1 0 0 Example of hexadecimal password 0x000102030405060708080a0b0c0d0e0f101112131415161718191a1b1c1d1e1f Do not use the example passwords above in a liv...

Страница 41: ...s the unit to other Bluetooth devices If left blank the unit will use a default name including the last 6 characters of the MAC ID Connectable Enable to make the unit accept connections initiated by o...

Страница 42: ...h devices To connect to a device select it from the dropdown menu when the scan has completed Connect To Used when connecting manually to a NAP or PANU device Connection Scheme Choose whether to selec...

Страница 43: ...NAP Mode Adjustment Description Bridge Mode Standard Default mode Layer 3 IP forward IP data will be bridged over Bluetooth This mode must be used when connecting to an Android device over Bluetooth...

Страница 44: ...25 Bluetooth LE Settings Adjustment Description Operating Mode Disabled Bluetooth LE disabled default Central Bluetooth LE enabled Please select Help in the main menu for more information about using...

Страница 45: ...se to select a downloaded firmware file then click on Send to send it to the unit Figure 19 Firmware update in progress Both progress bars will turn green when the firmware update has been completed T...

Страница 46: ...nced parameters that are not accessible in the web interface to read out parameters in text format and for batch configuration using command scripts Enter or paste the commands into the text box then...

Страница 47: ...ded Table 27 Settings Backup Adjustment Description Create Settings Backup Click on Generate to save the current configuration to a file on your computer Password is not included in backup file Restor...

Страница 48: ...leasing it Table 29 Default Network Settings Adjustment Description IP Assignment Static IP Address 192 168 0 99 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 99 Internal DHCP Server Enabled Tab...

Страница 49: ...will now be discoverable and open for automatic configuration Figure 24 Easy Config Mode 4 2 In the web interface of unit 2 activate Easy Config Mode 5 for WLAN or 6 for Bluetooth Unit 2 will now disc...

Страница 50: ...t settings 2 Connect Wireless Access Point 1 to the IO device and Wireless Access Point 2 to the PLC 3 Set Wireless Access Point 1 to Easy Config Mode 4 This unit will now be discoverable and open for...

Страница 51: ...cess Point 1 to the IO device and Wireless Access Point 2 to the PLC 3 Set Wireless Access Point 1 to Easy Config Mode 4 This unit will now be discoverable and open for automatic configuration 4 Set W...

Страница 52: ...s PROFINET Configuration 1 Reset the Wireless Access Point to the factory default settings 2 In Network Settings configure the IP settings as required by the wireless network 3 If the network uses DHC...

Страница 53: ...required by the wireless network 3 In WLAN Settings click on Scan for Networks 4 When the scan has completed select the wireless network from the dropdown list 5 If required select the authentication...

Страница 54: ...lt settings 2 In Network Settings configure the IP settings as required If the wired network uses DHCP select DHCP Relay Enabled The DHCP server on the network will now be able to allocate an IP addre...

Страница 55: ...k name for the new wireless network 5 Set Authentication Mode to WPA2 and enter a passkey 6 Select a Channel band and a Channel 7 Click on Save and Reboot You should now be able to connect to the SSID...

Страница 56: ...size and shape of the zones depend on the distance between the devices and on the signal wave length As a rule of thumb at least 60 of the first innermost Fresnel zone must be free of obstacles to ma...

Страница 57: ...ferent angles around the WAP while maintaining the same distance 6 3 1 Azimuth Horizontal View This diagram shows the horizontal antenna pattern when looking at the WAP from above i e looking at the t...

Страница 58: ...58 Appendix 758 919 Wireless Access Point Manual Version 1 0 0 Figure 34 Antenna Pattern Horizontal Please note the information Limited gain for 5 GHz between 105 to 190...

Страница 59: ...Appendix 59 758 919 Wireless Access Point Manual Version 1 0 0 6 3 1 1 Front View Vertical 0 Figure 35 Front View Vertical 0...

Страница 60: ...iagrams show the antenna pattern when looking at the WAP from the side in two different rotations 0 and 90 The WAP is mounted in a metal cabinet illustrated by the box below Figure 37 Vertical Views D...

Страница 61: ...less ETHERNET Gateway in a free field application Figure 38 Throughput Diagram 6 4 Data Security for Radio Transmission It is often assumed that wireless communication systems are less secure than lin...

Страница 62: ...gure 8 Bluetooth Settings PANU Mode 42 Figure 9 Bluetooth settings NAP 43 Figure 10 Bluetooth LE settings 44 Figure 11 Firmware update in progress 45 Figure 12 Firmware update completed 45 Figure 13 A...

Страница 63: ...Energy 24 Table 1 Selection of Installation Location 28 Table 1 Buttons 32 Table 2 Easy Config Modes 33 Table 3 Network Settings page 35 Table 4 Network Settings page 36 Table 5 Advanced Settings 37 T...

Страница 64: ...64 List of Tables 758 919 Wireless Access Point Manual Version 1 0 0...

Страница 65: ...List of Tables 65 758 919 Wireless Access Point Manual Version 1 0 0...

Страница 66: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 49 571 887 0 Fax 49 571 887 844169 E Mail info wago com Internet www wago com...

Отзывы: