Mechanical Installation
For optimal reception, wireless devices require a zone between them clear of
objects that could otherwise obstruct or reflect the signal. A minimum distance of
50 cm between the devices should also be observed to avoid interference.
The device is intended to be mounted on top of a machine or cabinet through an
M50 (50.5 mm) hole using the included sealing ring and nut.
The top mounting surface (in contact with the sealing) must be flat with a finish
equivalent to Ra 3.2 or finer and cleaned and free from oils and greases.
Tightening torque: 5 Nm ±10 %
Make sure that the sealing ring is correctly placed!
Make sure that the sealing ring is correctly placed in the circular groove in the top
part of the housing before tightening the nut.
Always hold the BOTTOM part of the unit when untightening the nut!
Always hold the BOTTOM part of the unit when untightening the nut, not the top
part (the cap)!
Figure 8: Installation drawing