7.2.4 Check sum(BCC)
It add all binary number within Check sum range and convert to 1 Byte of ASCII
code. The "35H" is check sum result (BCC) in the example shown.
STX CMD
Data
B
CC ETX
Example)
STX V
1
.
0
0
1 BCC ETX
----
- A
SCII code
STX 56 20
2
1 2E 30 30
31 BCC ETX
----- Hex
a c
ode
5 6 H
2 0 H
3 1 H
2 E H
3 0 H
+ 3 0 H
1 3
5
H ------- Hexa code
↓ ↓
33H
35
H ------------- Hexa value of "5" in ASCII code
7.2.5 Details of Command
1) Status request and response
1 : Target count number on P90 (Model #1) ( 00 - 99 )
2 : Current count number (remained) ( 00 - 99 )
3 : Current Speed set ( 0000 - 1800 )
4 : Current Torque set / unit 0.1 ( 000 - 150 )
5 : Fastening status
"0" : On fastening
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214