5) Minimum Angle for Fastening Quality contro
l
Number
Unit
Range
Initial
P31~38
0.1 turn
0 ~ 30.0
0
Description
Minimum angle can be set as a threshold point For
fastening quality control.
"0" : No use
"0.1~30.0" : Value of rotating turn (angle)
Function #1 No torque up NG after Min. Angle (P78)
If the driver stops without torque up after the preset turn, it
provide fastening NG output signal with the error code
E306
. It
is most serious mistake by operator which is open found but
difficult to be recognized..
If the driver stops without torque up before the preset turn, it
does not provide fastening NG. Because it is very common
operating together with screw feeder.
This operation does not have any intention of screw fastening.
0" : Disable "1" : Enable on P78
Function #2 Torque up NG before Min. Angle (P79)
If the driver reach up to the target torque after the set minimum
turn, the fastening quality is OK. If it stops at the target torque
before the set min. turn, it will provide the fastening NG output
signal with the error code
E307
.
This is useful function for detecting wrong engaged and
fastened screw.
"0" : Disable "1" : Enable on P79
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
26
Содержание HDC-35i
Страница 15: ...4 LAY OUT 4 2 HDC Controller LAY OUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 15...
Страница 55: ...5 11 5 25P Interface schematic OUTPUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 55...
Страница 65: ...2 Direct wiring to 25P I O interface port 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 65...
Страница 81: ...1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 81...
Страница 86: ...2 Real Time Data monitoring Monitoring 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 86...