6) Cycle Reset & key button lock on front panel
Number
Unit
Range
Initial
P29
0 or 1
0
Description
Cycle reset is allowed by the Reset key button on the front
panel " 0 " Disable, " 1 " Enable
P49
0 or 1
0
Description
Front key button lock control on the front panel
on the front panel " 0 " Disable, " 1 " Enable
7) Soft start setting 41 ~ 48
8) Torque Tuning 51 ~ 58
Number
Unit
Range
Initial
P51~58
1 %
-10 ~ +10%
0
Description
O
utput torque can be decrease
d
or increased between -10%
to +10% for each preset #.
This t
o
rque tuning value is saved in controller, not in drive
r
.
Be careful tuning value when replace the screwdriver.
Number
Unit
Range
Initial
P41~48
1 ms
0 ~ 300ms
0
Description
Soft start time to the target speed is selectable fro
m
0 - 300mS for each preset
#
rpm
time