4)
Two pulse type signal ( select "3" on P76 )
As shown the picture below, there are two pulse type signals. The left one is for
Count Start and the right one is for Count stop signal. The right one detects work
piece moving out of work area for verifying NG. If the count number does not reach
to the target, it will provide error code
E r 3 0 5
The Count Start sensor or switch is wired to the COUNT port on the back.
The Count Stop sensor or switch is wired to pin 9 of the 25P I/O connector.
(refer to the page 37,38 for details)
The preset no. selecting on P64 should be "0", direct Sensor port
*** Refer to the page 47, 48 for wiring.
It is same as the preset no. selecting by sensor
The above two sensors can be replaced to switches.