8. Auto fastening data output through USB port (P86)
Check mark on Enable on P86 ( auto fastening data output ), then every fastening
data will be out at every event through RS-232 without data request command.
The output data consist of 13 fastening information as below
Each data is divided by comma(,) between data.
example )
ㄱ
m9039001,01350,1,085,084,1700,033,0358,000,04,032,1,1,9
ㄴ
1. Start of Text (STX)
2. Data
: m (monitoring) data
3. Serial no.
: 9039001 ( 2009, March )
4. Fastening time : 1350 ms
5. Preset #
: 1
6. Torque setting : 8.5
7. Fastening torque (converted torque) : 8.4
8. RPM setting : 1700 rpm
9. Fastening angle : 3.3 turn
10. Motor temperature : 35.8
℃
11. Error code : 000 ( No error, Fastening OK ) if 301, error 301
12. Screw count # : 4 screws remained
13. Motor current : 3.2 Ampere
14. For / Rev : Fastening (1), Loosening (0)
15. Torque complete : Torque complete (1), No torque up (0)
16. Data check sum : See article 7.2.4
17. End of Text (EXT)
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
76
Содержание HDC-35i
Страница 15: ...4 LAY OUT 4 2 HDC Controller LAY OUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 15...
Страница 55: ...5 11 5 25P Interface schematic OUTPUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 55...
Страница 65: ...2 Direct wiring to 25P I O interface port 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 65...
Страница 81: ...1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 81...
Страница 86: ...2 Real Time Data monitoring Monitoring 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 86...