33) Parameter reset to the factory setting
Number
Unit
Range
Initial
P83
0
or
77
0
Description
Every parameter will be reset to the factory setting.
Put the password "77" on parameter 83 and Enter for reset to
factory setting.
- Controller should be reset to the factory setting when the
connected driver is replaced to other model.
- Controller should be powered off whenever completed resetting.
34) F1 Button on screwdriver (P84 : HDC-40i only)
Number
Unit
Range
Initial
P84
0 ~ 1
1
Description
Ena
ble or disable of the F1 button function of selecting
preset # 1 to 8 ( move up in circulation )
"0" : Disable, "1" : Enable
35) Reverse torque control
Number
Unit
Range
Initial
P85
0 ~ 1
1
Description
The auto shut-off at torque up signal can be disabled for
reverse rotation.
0 : Disable
1 : Enable