9) Middle count number setting
Number
Unit
Range
Initial
P39
0 ~ 99
0
Description
When the count number reaches to the Middle count number,
count complete signal OUT become ON till the total count is
completed. Signal types on P70 are ignored on this feature
"0" : No use " 1~99" : Middle count number
10) Function of Max Angle setting of P21 ~ 28
Number
Unit
Range
Initial
P40
0 ~ 1
0
Description
It stops at the set Max angle, and verify as one of below
"0" : OK "1" : NG and display Error no 301
11) COM port select
Number
Unit
Range
Initial
P59
0 or 1
1
from V2.60(2014.10)
Description
One of two communication port should be selected between
RS-232C and USB (converted from RS-232C)
0 : USB (converted from RS-232C) 1 : RS-232C