5.13.5 Operation of Model selecting
When model select feature is enabled on P75 (model select), total 20 preset
numbers can be programmed to be selected in sequence on the model #.
Total 8 models can be programmed in the HDC v2.1.
The selecting models can be changed only through the remote interface I/O.
■
Auto sequence fastening
1) Select Enable (1) of "Select model" on P75
2) Select Enable (1) of "Select Auto sequence" on P74 for auto sequence fastening
3) Key in the screw numbers on total count window for Model 1 to 8
4) Select preset numbers from 1st to the end for auto sequence fastening.
The fastening number is possible up to 20 screws.
■ Non
auto sequence fastening
1) Select Enable (1) of "Select model" on P75
2) Select Disable (0) of "Select Auto sequence" on P74 for Non auto sequence fastening
3) Key in the screw numbers on total count window for Model 1 to 8
4) Leave "0" on every windows
Preset # can be changed by sensor or PLC according to the selection on P64.
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
67
Содержание HDC-35i
Страница 15: ...4 LAY OUT 4 2 HDC Controller LAY OUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 15...
Страница 55: ...5 11 5 25P Interface schematic OUTPUT 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 55...
Страница 65: ...2 Direct wiring to 25P I O interface port 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 65...
Страница 81: ...1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 81...
Страница 86: ...2 Real Time Data monitoring Monitoring 1080 N 11th St San Jose CA 95112 www mountztorque com 408 292 2214 86...