Motorola MTR2000 Скачать руководство пользователя страница 34

Installation

68P81096E37-N

7

06/28/05

5.1 cm

(2 in)

5.1 cm

(2 in)

5.1 cm

(2 in)

9.6 cm

(3.8 in)

5.1 cm

(2 in)

5.1 cm

(2 in)

Figure 1.        Floor-mount Cabinet – Dimensions and Clearances

55.9 cm

(22 in)

46.5 cm

(18.3 in)

45.2 cm

(17.8 in)

55.9 cm

(22 in)

46.5 cm

(18.3 in)

FRONT

Mounting 

Rails (4)

76.2 cm

(30 in)

0.64 cm

(0.25 in)

FRONT VIEW

SIDE VIEW

BASE MOUNTING DETAIL

VIEWED FROM 

TOP

5.1 cm

(2 in)

49 cm

(19.3 in)

5.1 cm

(2 in)

9.6 cm

(3.8 in)

5.1 cm

(2 in)

9.2 cm 

(3.625 in) 

holes (2)

1.575 cm 

(0.62 in) 

holes (4)

1.524 m

(60 in)

1.168 m 

(46 in)

49 cm

(19.3 in)

Station 

Support 

Brackets (2)

Содержание MTR2000

Страница 1: ...Installation and Operation Manual 68P81096E20 N MTR2000 Base Station Repeater and Receiver For Analog Conventional and Trunking Systems ...

Страница 2: ...seller or if appropriate to specifications accepted by Seller in writing during the period shown Motorola at its option will either repair or replace the product or refund the purchase price thereof and such action on the part of Motorola shall be the full extent of Motorola s liability hereunder This warranty is void if a the product is used in other than its normal and customary manner b the pro...

Страница 3: ...ials include any material that contains copper primarily consist of circuit boards exclude cables separate Material category Beryllium Oxide has been used in the power amplifier Beryllium Oxide should not be subjected to any process which will generate dust Features Over 92 of the station is made of aluminum one of the most recycled materials commonly available today In addition the aluminum used ...

Страница 4: ...ries or regions collection sys tems have been set up to handle waste of electrical and electronic equipment In European Union countries please contact your local equipment supplier represen tative or service center for information about the waste collection system in your country Disposal Guideline The following symbol on a Motorola product indicates that the product should not be disposed of with...

Страница 5: ...ual to highlight certain information The area to the left of the text column contains key words and graphic symbols which allow the reader to quickly identify desired information The following text highlight symbols are used A note symbol indicates important information that helps improve the described function A caution symbol indicates a potential problem unless the proper ac tions are taken A c...

Страница 6: ... or marine radio when someone is within two feet 0 6 meter of the antenna DO NOT operate the transmitter of any radio unless all rf connectors are secure and any open connectors are properly terminated In addition DO NOT operate this equipment near electrical blasting caps or in an explosive atmosphere All equipment must be properly grounded according to Motorola installation instructions for safe...

Страница 7: ...onventions ix General Safety Information x DESCRIPTION 68P81096E36 INTRODUCTION 1 Flexible Mechanical Design 1 Electrical Design 2 Trunking Capability 2 Summary of Operating Features 3 DESCRIPTION MTR2000 Station Repeater and Receiver For Analog Conventional and Trunking Systems MOTOROLA MTR2000 Spectra TAC DigiTAC and Private Line are trademarks of Motorola Inc TORX is a trademark of Camcar Divis...

Страница 8: ...ATION 68P81096E37 PRE INSTALLATION CONSIDERATIONS 1 Installation Overview 1 Environmental Conditions at Intended Installation Site 2 Equipment Ventilation 3 AC Input Power Requirements 4 Equipment Mounting Methods 5 Floor mount Cabinet 6 Modular Racks 8 Site Grounding and Lightning Protection 10 Site Grounding Lightning Protection Recommendations 10 Equipment Grounding Guidelines 10 Recommended To...

Страница 9: ...NFIGURATION 21 4 Wire Wireline Interface Board 21 4 Wire Euro Wireline Interface Board 21 Auxiliary I O Board 23 ELECTRICAL CONNECTIONS 26 Power Supply Connections 28 AC Input Power Connection 28 Ground Connection 29 DC Input Power Connection 29 Battery Connection 29 RF Antenna Connections 31 System Cable Connections 32 Telephone Line Connections 37 Introduction 38 Telephone Line Specifications 39...

Страница 10: ...imizing Tasks 47 Copying Station Codeplug Date To a PC compatible Computer 47 INSTALLING STATION HARDWARE OPTIONS 48 STATION OPERATION 68P81096E38 DESCRIPTION 1 LED Indicators 2 External Device Connections 3 Service Connections 4 STATION OPERATION ...

Страница 11: ...Figure 4 Unpacking Procedures Floor mount Cabinets 14 Figure 5 Slide Rail Installation Option X968AA Left Side Shown 18 Figure 6 Slide Rail Installation Option X346AB Left Side Shown 20 Figure 7 CLN1203 Wireline Interface Board Jumper Settings 21 Figure 8 CLN1204 Wireline Interface Board Jumper Settings 22 Figure 9 CLN1206 Auxiliary I O Board Jumpers 23 Figure 10 Location of External Connectors at...

Страница 12: ...ly Used Pins 33 Table 5 Summary of Auxiliary Inputs Outputs at the System Connector 34 Table 6 J5 SYSTEM CONNECTOR Row A Pins 35 Table 7 J5 SYSTEM CONNECTOR Row B Pins 36 Table 8 J5 SYSTEM CONNECTOR Row C Pins 37 Table 9 Type 5 and 3002 Phone Line Specifications 39 Table 10 Wireline Connector Line Pair Assignments 40 Table 11 System Types vs Wireline Circuit Matrix 41 Table 12 Station Maintenance ...

Страница 13: ... allows for superior station flexibility and simplified system upgrades All of the features described in this manual may not be currently supported Refer to the Summary of Operating Features section for a list of standard features op tional features and planned future features Flexible Mechanical Design All elements of the station are designed for EIA 48 3cm 19 rack mounting allow ing the equipmen...

Страница 14: ...t to the Station Control Module providing improved consistent audio quality through out the coverage area Station Control Module The Station Control Module is microprocessor based and features extensive use of ASIC and digital signal processing technology The module serves as the main con troller for the station providing signal processing and operational control for the sta tion modules Wireline ...

Страница 15: ...e of the leading optional features for the station Double Circulator Option provides additional isolation and intermodulation protection for rf congested transmitter sites not available on 350MHz stations Microprocessor Radio Telephone Interconnect MRTI allows connection of conventional station to the telephone network Trunking allows trunking repeater to operate as part of a Smartnet or Smart Zon...

Страница 16: ...dule Bottom Plate Exciter Module Receiver Module Station Control Module Power Amplifier Module Front Cover NOTE Fans and fan covers are only used on high power Power Amplifier modules and Power Supplies Backplane NOTE Fans and fan covers are only used on high power Power Amplifier modules and Power Supplies Fan Cover Auxiliary I O Board Top Plate Fan Wireline Interface Board ...

Страница 17: ... via the SPI bus and generate an rf carrier at the specified frequency The VCO is directly modulated by transmit audio data from the SCM The resulting modulated rf signal at a level of approximately 12 dBm is then fed to the PA Power Amplifier Module Operation The PA modules are designed for continuous duty operation across all bands and power levels The actual circuit stages employed in a PA depe...

Страница 18: ...tional to the output power to the power control circuitry to serve as the feed back signal in the power control loop Under normal operating conditions the pow er control circuitry compares this dc voltage from the directional coupler to a reference voltage from the D A converter which represents the desired output pow er Based on the comparison a power control voltage is generated to control the o...

Страница 19: ...gh a low pass filter varactor tuned preselector if external preselector is not used rf amplifier and image filter to the rf input of the first mixer The filtered signal is mixed with an injection signal generated by the receive synthesizer VCO resulting in a first i f in termediate frequency signal The injection signal frequency is determined by fre quency programming data from the Station Control...

Страница 20: ...M and operates from station soft ware stored in FLASH memory This software determines the system capabilities of the station The Host µP communicates with the station modules and the SCM cir cuitry via address and data buses three SCI Serial Communication Interface ports and an SPI bus The DSP portion of the MC68356 with the support of the DSP ASIC perform the nec essary digital processing for the...

Страница 21: ...B via copper pairs at the rear of the station Wireline Interface Board Operation The WIB contains a PCM Codec filter device to perform the audio digitization and re construction as well as the band limiting and smoothing required by PCM systems Analog signals are routed as follows Inbound analog signals are converted to digital signals and routed to the SCM as wireline transmit data WL TxD Outboun...

Страница 22: ...n input signal path from auxiliary equipment to the station SCM The input circuitry supports 16 general purpose inputs 14 are transistor buffered inputs 16V maximum 10kΩ 2 are opto isolated inputs 60mA forward current 3V dropout voltage 2kV iso lation The Auxiliary I O Board contains SPI Output Latches and associated circuitry which provides an output signal path from the station SCM to auxiliary ...

Страница 23: ...as a Satellite Receiver ac Input Power The 250 W models generates the 5 1 V and 14 2 V operating voltages for the sta tion modules The 500 W models generates the 5 1 V 14 2 V and 28 V operating voltages for the station modules These modules have power factor correction and include a connection for battery backup Table 1 Power Supply Module Models Model Supplied by Input Voltage Range Output Voltag...

Страница 24: ...ule DLN6624 accepts a dc in put 10 8 to 16 Vdc The output voltages are the input filtered voltage a regulated 5 1 Vdc For dc only operation the 500 W Power Supply Module DLN6622 accepts a dc in put 21 to 32 Vdc The output voltages are the input filtered voltage a regulated 5 1 Vdc a regulated 14 2 Vdc ...

Страница 25: ...Description THIS PAGE INTENTIONALLY LEFT BLANK 68P81096E36 H 13 06 28 05 ...

Страница 26: ...EIVER SIGNAL STRENGTH INDICATOR OPTION DEPENDENT AUXILIARY TX AUDIO DISC AUDIO MICROPHONE AUDIO EXTERNAL SPEAKER 2 1 MHz REF 20 KHz CODEC BUS 24 KHz CODEC BUS 2 1 MHz REF DSP MEMORY DSP ADDRESS BUS DSP DATA BUS 24 KHz CODEC BUS DSP HOST MICROPROCESSOR SSI 68356 SPI BUS SPI BUS LINE RX LINE TX 4 WIRE VERSION SHOWN LINE 1 IN INBOUND WIRELINE AUDIO FROM LANDLINE TO STATION OUTBOUND WIRELINE AUDIO FRO...

Страница 27: ...NTENNA 75 W POWER AMPLIFIER 800 900 MHz B SPI BUS POWER CONTROL CIRCUITRY TWO CIRCULATORS 50 OHM LOAD 15 W INTERMEDIATE POWER AMP 50 W BUTTERFLY MODULE LOW PASS FILTER DIRECTIONAL COUPLER B SPI BUS POWER CONTROL CIRCUITRY CIRCULATOR 50 OHM LOAD 10 W INTERMEDIATE POWER AMP LOW PASS FILTER DIRECTIONAL COUPLER DUAL DEVICE MODULE 100 W POWER AMPLIFIER 600 MHz B SPI BUS POWER CONTROL CIRCUITRY Figure 3...

Страница 28: ...Standards Fixed Network Equipment Installation manual R56 68P81089E50 specif ically refer to the information on ground connection for lightning protection Installation Overview The following information is an overview for installing the station and an cillary equipment Step by step procedures for each of the major installa tion tasks are then provided beginning in Section 2 Mechanical Installation...

Страница 29: ...al circuit boards and modules is not easily removed and can cause such malfunc tions as overheating and intermittent electrical connections The station may be installed in any location suitable for electronic commu nications equipment provided that the environmental conditions do not exceed the equipment specifications for temperature humidity and air quality These are Operating Temperature Range ...

Страница 30: ...ded More than one station per cabinet will result in degradation of thermal specifications at high ambient temperatures Low Power Stations In order to maintain thermal specification of 30 C 22 F to 60 C 140 F the low power stations must be mounted in a cabinet with additional cooling A single low power station mounted in a cabinet without additional cooling will operate at thermal specifica tion p...

Страница 31: ...tlet must be connected to an ac source capable of supplying a max imum of 1020 VA For a nominal 110 120Vac input the ac source must supply 8 5A and should be protected by a circuit breaker rated at 15A For a nominal 220 240Vac input the ac source must supply 4 25A and should be protected by a circuit breaker rated at 10A Requirement for European Union EU Countries Beginning January 1 2001 input ha...

Страница 32: ...Each floor mount cabinet has front and rear vented doors and has the capacity to hold a minimum of a single station see thermal limitations described under Equip ment Ventilation and required ancillary equipment The larger cab inets provide additional room for supplementary peripheral equipment in a rack Open frame racks accept multiple stations and ancillary equipment EIA 48 3cm 19in rack configu...

Страница 33: ...nd 91 44cm 36in rear for minimum installation access Refer to Equipment Ventila tion for recommended ventilation clearances For improved access to the unit a tray slide is available option X968AA Ensure that the cabinet is securely anchored to the floor thereby avoid ing possible equipment tipping and personal injury Refer to Mounting Procedures Mounting Floor mount Cabinets for details on proper ...

Страница 34: ... 55 9 cm 22 in 46 5 cm 18 3 in 45 2 cm 17 8 in 55 9 cm 22 in 46 5 cm 18 3 in FRONT Mounting Rails 4 76 2 cm 30 in 0 64 cm 0 25 in FRONT VIEW SIDE VIEW BASE MOUNTING DETAIL VIEWED FROM TOP 5 1 cm 2 in 49 cm 19 3 in 5 1 cm 2 in 9 6 cm 3 8 in 5 1 cm 2 in 9 2 cm 3 625 in holes 2 1 575 cm 0 62 in holes 4 1 524m 60 in 1 168m 46 in 49 cm 19 3 in Station Support Brackets 2 ...

Страница 35: ...ront and rear is 91 44cm 36in minimum for servicing access Refer to Equipment Ventilation for recommended venti lation clearances FRU kit CLN6679A MTR2000 Rack Mounting Hardware is included with each Rack Option This allows proper installation of the MTR2000 station within the rack s centre of gravity This kit includes two rack mount standoffs and eight mounting screws Rack Option Rack Height Numb...

Страница 36: ... 17 78cm 7in 3 81cm 1 5in 17 78cm 7in 7 22cm 2 85in 38 74cm 15 25in 5cm 2in 15 9mm Diam 0 625in 9 4mmDiam 0 37in 52 7cm 20 75in 45 36cm 17 86in 48 77cm 19 2in 38 74cm 15 25in 13 45cm 5 3in 5cm 2in 9 4mmDiam 0 37in Rack Center SIDE VIEW TOP BOTTOM VIEW Dimension B Dimension B Dimension B Dimension A 10 97cm 4 375in 13 21cm 5 25in 0784384T03 13 21cm 5 25in Standoff ...

Страница 37: ...of rf grounding is the use of shielding to prevent or at least minimize the leakage of unwanted rf transmissions from communications equipment and cables Lightning Ground Providing adequate lightning protection is critical to a safe and reliable communications site Telephone lines rf transmission cables and ac and dc power lines must all be protected to prevent lightning energy from en tering the ...

Страница 38: ...cabinet bolted to a wooden skid and covered with a cardboard box with corrugated interior corner braces Stations to be used in open frame racks are shipped with the station and ancillary equipment mounted in the rack and covered by an an tistatic plastic bag All rack shipments are electronic van only Thoroughly inspect the equipment as soon as possible after delivery If any part of the equipment h...

Страница 39: ...nspor tation company and to Motorola Unpacking Stations The station is shipped in a carton cushioned by four plastic inserts at the corners of the carton Improper handling of the station may cause personal injury or damage to the station DO NOT pick up the station by holding the Preselector if so equipped Use the handles on the front of the station or the Pow er Supply and Power Amplifier casings ...

Страница 40: ...05 Unpacking Floor mount Cabinets The floor mount cabinets are shipped mounted to a wooden skid secured with corrugated corner braces held by a plastic strap and covered with a cardboard cover Unpack the equipment as described in Figure 3 ...

Страница 41: ...uring installation 5 Depending on cabinet type either open or remove front and rear doors to gain access to the four 4 bolts securing the station to the wooden skid Remove the bolts and nuts as shown 6 Use hoist to lift the station from the skid Remove skid and return station to floor 7 Replace antistatic bag over station to provide protection during installation Cardboard Cover Corrugated Corner ...

Страница 42: ...se the rack mounting foot as a template and mark the location of the six 19mm 3 4in diameter mounting holes All six anchoring posi tions must be used 3 Move the rack aside drill holes in the concrete floor and install the mounting anchors RAM RD 56 anchors recommended per instruc tions provided with the anchors Make sure that none of the anchors comes in contact with the reinforcing wire mesh buri...

Страница 43: ...rocedures above for anchoring equipment racks If installing on a wooden floor use lag bolts and washers customer supplied to secure the cabinet to the floor Transferring Equipment from Shipping Container to Rack or Cabinet As mentioned under Equipment Unpacking and Inspection a station can be shipped in a box Upon delivery the equipment must be removed from the container and transferred to a Motor...

Страница 44: ...ng 4 Attach each Outer Slide Rail to a Cabinet Bracket with supplied screws The left and right Cabinet Brackets are identical The Locking Tab of each Outer Slide Rail must face towards the rear of the cabinet Working in the cabinet 5 The cabinet must have a set of vertical cabinet rails in the back as well as the front If there is no set in the back these must be installed The back rail is install...

Страница 45: ...s countersunk 2 Inner Slide Rail Mounting Screws panhead 2 station side Inner Slide Rail Outer Slide Rail Cabinet Bracket Cabinet Rail front Note The left side slide rail assembly is shown as viewed from the front of the cabinet The left side is a mirror image of the right side Slide Locking Latch Cabinet Rail rear Direction That Station Slides Out LEFT Note Middle Slide Rail not shown for clarity...

Страница 46: ...ll tightened when the brackets are mounted in the cab inet step 7 The left and right Cabinet Bracket sets are identical The Locking Tab of each Outer Slide Rail must face towards the rear of the cabinet Working in the cabinet 5 Install a cage nut in line with clearance hole in Threaded Strip prior to fitting the Front Bracket to the front cabinet rail This nut is required for mounting the station ...

Страница 47: ...he cabinet The left side is a mirror image of the right side Direction That Station Slides Out Station Mounting Screws 2 Mount Outer Slide Rails to Brackets ONLY use lower slot of Brackets Long Bracket Short Bracket Install a cage nut in line with clearance hole in Threaded Strip prior to fitting bracket to the front cabinet rail This nut is required for mounting the station The cage nuts are prov...

Страница 48: ...ws the jump er locations for tone control 4 Wire Euro Wireline Interface Board Figure 7 shows the correct settings of impedance matching jumpers for the model CLN1204 WIB as determined by the country in which the station is being operated Incorrect jumper settings may violate local telecommuni cations authority regulations and place the equipment in an unapproved status Some countries also specify...

Страница 49: ...2ηF 150Ω 600Ω 500Ω 330ηF 400Ω 620Ω 310ηF 370Ω 820Ω 115ηF 220Ω 820Ω 115ηF 220Ω 820Ω 115ηF 220Ω 900Ω 30ηF Figure 7 CLN1204 Wireline Interface Board Jumper Settings C74 T1 T2 C15 C84 P3 E D C B A P7 P1 P9 P5 P8 E D C B A E D C B A E D C B A Jumper In A Pin 1 connects to Pin 2 This setting represents a standard 600 ohm matching and is the factory default B Pin 3 connects to Pin 4 C Pin 5 connects to P...

Страница 50: ... can be jumpered to be a transistor input or opto isolated In addition it can be dedicated to the Ext_PTT Line routed to the SCM This function is a fast external PTT an active low function The board jumper settings for P2 P9 P6 are provided in Table 1 Settings for P5 are provided in Table 2 Settings for P3 P4 are provided in Table 3 P7 and P8 are not used Figure 8 CLN1206 Auxiliary I O Board Jumpe...

Страница 51: ... must be jumpered to the SPI Buffer The Buffer Input should never be left floating otherwise the IRQ Generator will not function properly i e use either P2 1 2 or P9 7 8 Function on GPI_14 Input Type System Connector Input Pins Auxiliary I O Board Jumpers P2 P9 P6 See Note 1 Fast External PTT via Optocoupler E M sub See Note 2 A29 Opto A26 Opto 3 4 1 2 In via Transistor B26 9 10 7 8 In Fast Extern...

Страница 52: ...uration is only available when the board is plugged into Option slot 1 Function on GPO_15 Output Type System Connector J5 Output Pins Auxiliary I O Board Jumpers P3 P4 Fast Carrier Detect via Relay Closure C3 B3 2 4 2 4 via Open Collector B21 see Note 4 3 4 2 4 RdStat via Relay Closure see Note 3 C3 B3 2 4 1 3 via Open Collector B21 see Note 4 3 4 1 3 SPI Latch for GPO_15 soft ware defined via Rel...

Страница 53: ...ns associated with maintenance and troubleshooting of the station These con nectors are located on the front of the Station Control Module see Station Operation section for position of these connectors 4 ELECTRICAL CONNECTIONS STOP IMPORTANT When installing option boards ensure that an Electro Static Discharge ESD cable is connected via banana plug to the hole in the front right handle of the stat...

Страница 54: ...al connectors located at the rear of the station Figure 9 Location of External Connectors at Rear of Station Battery Backup and DC Input Connector Rx RF Connector Tx RF Connector Wireline Connector System Connector Trunking MRTI Connector AC Power Connector Not used in DC mode Ground Screw ...

Страница 55: ...ows the ac line cord connector Insert the plug into an appropriate grounded outlet The North American line cord is equipped with a NEMA 5 15 plug in tended for 110 120Vac operation The optional European line cord Option X189AA is equipped with a Schuko style CEE VII 7 plug intended for 220 240VAC operation Plugs for other countries are available as the following options If an alternate line cord i...

Страница 56: ...21 0 to 32 0 Vdc for the high power station Battery Connection Battery backup interface offers the capability of connecting to battery backup power in the event of an AC power line failure The battery backup system is connected to the station through the red and black connector mounted at the rear of the station The connector has a cover with the following label This label di rects the technician ...

Страница 57: ...ion to the storage battery Connect as shown in Figure 10 CAUTION Figure 10 Making Connections to Storage Battery DC input Connector located at rear of the station for hooking up the Battery backup system Required input power Voltage 14 2 Vdc Low Power LP 28 4 Vdc High Power HP Current 11 5 Amps LP 13 0 Amps HP Both positive and negative terminals must be protected with appropriate fast acting fuse...

Страница 58: ...nnectors Coax cables from the receive and transmit anten nas must be connected to the two N type connectors The position of these connectors is shown in Figure 9 In the case where an optional Antenna Relay is used on the station the coax cable from the single transmit receive antenna is connected to the middle N type connector of the Antenna Relay ...

Страница 59: ...t 3083765X06 30 48m 100ft Trunk Cable part 3083765X07 The following cable is available for MRTI applications Interface cable for Zetron model 30 kit TTO4097 System Connector The cable connected to the System connector can be configured for various system options A generic System cable is available for variety of applications such as Wild Card Main Standby and Auxiliary Input Output generic System ...

Страница 60: ... 5 1 0 25 volts dc output A20 B20 C20 Total current through all of these pins should not exceed 500 mA GND Ground A19 B19 C19 A27 B27 C27 A31 B31 C31 Total current through all of these pins should not exceed 1 5 Amp Aux Tx Audio Tx modulation input from external source A17 RSS programmable sensitivity For R03 01 host software and earlier the fixed sensitivity is 172 mVrms for 60 system deviation R...

Страница 61: ...orted this pin should not be used Aux I O Indicates that the Aux I O board must be present for this functionality WCI Wild Card Input WCO Wild Card Output The RSS Online Help provides the most current information on the System Connector pin assignments Table 5 Summary of Auxiliary Inputs Outputs at the System Connector Auxiliary I O GPI_ System Connector J5 Pin Auxiliary I O GPO System Connector J...

Страница 62: ... J1 C18 J2 C18 J3 C19 15 Spare 310 16 Spare 308 17 Aux TX Audio I J1 C16 J2 C16 J3 C16 RSS programmable input sensitivity 18 Cntrl 14 2 VDC O P8 pins 3 4 thru F2 14 2Vdc Note 1 19 GND Station ground 20 5 VDC O P8 pins 7 8 5 1 0 25 Vdc 21 Not Supported O J3 C12 22 GP1_7 WCI I J1 C11 J2 C11 Pulled up transistor input 16V max 23 Spare 323 24 Spare 320 25 Spare 903 26 Ext PTT or GP1_14 Note 2 I J1 C7 ...

Страница 63: ...I O J1 B22 J2 B22 Caution See Auxiliary I O section for jumpering infor mation 12 GPI_11 WCI or GPO_5 NS I O J1 B23 J2 B23 13 Spare 301 N C 14 Not Supported I J1 B19 J2 B19 J3 B19 TTL input 15 GND Station ground 16 Spare 300 17 Spare 321 18 Cntrl 14 2 VDC O P8 pins 3 4 thru F2 14 2Vdc Note 1 19 GND Station ground 20 5 VDC O P8 pins 7 8 5 1 0 25 Vdc 21 RdStat or GPO_15 Note 4 O J1 B12 OCO 100mA 40V...

Страница 64: ...dc for 120dBm to 3 5 Vdc for 40 dBm car rier Variation with carrier level approximately 40mV dBm 12 GPI_10 WCI or GPO_4 NS I O J1 A24 J2 A24 Caution See Auxiliary I O section for jumpering infor mation 13 Spare 304 14 Not Supported O J1 A19 J2 A19 J3 A19 15 GND Station ground 16 GND Station ground 17 Disc RX Audio O J1 A16 J2 A16 J3 A16 Discriminator audio flat response 80mV to 400mV for 60 deviat...

Страница 65: ...t be connected between the station and the remote equipment The phone lines may carry analog voice or encoded voice Also carried on the phone lines are Tone Remote Control type of remote control signalling The fol lowing information defines the specifications for the phone lines the loca tion on the station backplane for phone line connections and which of the four 4 wireline circuits to use for v...

Страница 66: ...e line types Table 9 Type 5 and 3002 Phone Line Specifications Parameter Type 5 Specification 3002 Specification Loss Deviation 4 0dB 4 0dB C Notched Noise 51dBmCO 51dBmCO Attenuation Distortion 504 to 2504 Hz 404 to 2804 Hz 304 to 3004 Hz 2 0 to 8 0dB 2 0 to 10 0dB 3 0 to 12 0dB 2 0 to 8 0dB 2 0 to 10 0dB 3 0 to 12 0dB Signal To C Notched Noise Ratio 24dB 24dB Envelope Delay Distortion 804 to 260...

Страница 67: ... tool part number 6600809D00 Before applying excessive pullout force on the telephone connection wires be sure to release wires properly System Connector When 8 wire 4 line telephone connections are required Line 1 and Line 2 are provided through the 4 terminal Telephone con nector Line 3 and Line 4 are provided through the System connector The location of the Telephone and System connectors on th...

Страница 68: ...udio with respect to consoles comparators CIT and DVM modems are outputs Transmit audio with respect to stations is an input iv Receive audio with respect to consoles comparators CIT and DVM modems are inputs Receive audio with respect to stations is an output Note Table 11 System Types vs Wireline Circuit Matrix System Type Line 1 Note i Line 2 Note i Line 3 Line 4 Conventional Local Area Analog ...

Страница 69: ...imum level should not exceed 3Vpp Service Speaker P5601 Output to Power Voice speaker Adjustable between 0 to 500mV across 1Kohm 60 system deviation Audio signal appears between pins 3 and 4 on the connector Must use speaker type HSN1000 via adapter cable Part No 0185180U01 RSS P5600 Serial Port For connection to serial port of a computer via cable Part No 3082056X02 The Radio Service Software RSS...

Страница 70: ...c outlet that is supplying power to the station Power Supply Module or switch on the DC supply to a station with a DC only Power Supply Module Changing Fuse To replace the station fuse 1 Turn off station power at source e g ac breaker 2 Remove fuse cover plate located on the backplane shield by unscrew ing one M4 screw 3 Pull defective fuse carefully with small needle nose pliers 4 Replace new fus...

Страница 71: ... at the same time 2 All go off for about 15 seconds 3 All stay off except for the Station Status LED which goes red for about 6 seconds 4 Now indicate operational status of the station The 4 LEDs indicate PA Keyed LED green station PA is keyed FailSoft LED yellow if set up for trunking station is not be ing controlled from the trunking central controller Rx Active LED green station is unsquelched ...

Страница 72: ... wireline loopback failure invalid local channel selection Boot mode is the mode the station is in during the loading of software into the station s Flash memory Service mode is the mode the station is in during normal maintenance and service periods These modes include the following conditions Intercom PL Disable Access Disable Failsoft Disable Power Control Disable Service PTT The Radio Service ...

Страница 73: ...n of the station radio can be verified by exercising the radio s two way operation This may be carried out when an external speaker and mi crophone are connected to the Station Control Module SCM The kit for the speaker is HSN1000 The external speaker requires an adaptor cable part 0185180U01 Using a speaker other than the recommended HSN1000 may result in the station blowing a fuse The kit number...

Страница 74: ...g the station codeplug from the station this ensures a match between the station serial number resident in the codeplug and the serial number part of the customized station codeplug data that is written back to the station see task 5 2 Customizing the station codeplug and saving the data to the station 3 Aligning the station for Rx Wireline Tx Wireline Receiver RSSI calibration option Receiver Squ...

Страница 75: ...ith an External Double Circulator option this circulator is provided in a peripheral tray In the case where an option is later added to the station it can be installed according to the information provided in the Ancillary Equipment sections of the appropriate Instruction manual Also refer to the Troubleshooting sec tion for information on tuning the External Preselector 7 INSTALLING STATION HARDW...

Страница 76: ...s and connectors provided on the station The set of LEDs indicate the operational status of the station There are two sets of connectors for devices external to the station One set connects to external devices to enable full operation of the station These are located at the back of the station Another set connects to external devices for servicing the station These are located on the Station Contr...

Страница 77: ...ost Installation Checklist Verifying Proper Op eration Red Green Station Status LED Yellow FailSoft LED Green Rx Active LED Figure 1 Front Panel LEDs Green PA Keyed LED FS Function Color Indicates Station Status red green operational status of station Rx Active green that the station Rx activation criteria are satisfied This could be RF carrier only PL DPL only or RF carrier plus PL DPL FailSoft y...

Страница 78: ...lectrical Connections for the position of the station external connectors and line cord located on the back panel A BNC connector on the front of the SCM allows the station to be connect ed to a 5 MHz or 10 MHz external reference signal Figure 2 shows the position of the BNC connector on the SCM ...

Страница 79: ...odule and an external speaker amplifier with a 6 pin molex con nector via an adaptor cable part number 0185180U01 RSS connects between the telephone connector on the Station Control Module and the DB9 connector on a PC A DB25 connector can also be used to connect to the PC when used with a DB25 DB9 adaptor Service Microphone connects between the telephone connector on the Station Control Module an...

Отзывы: