![Motorola MTR2000 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/motorola/mtr2000/mtr2000_installation-and-operation-manual_241115023.webp)
Description
68P81096E36-H
11
06/28/05
Power Supply Module Operation
Power Supply Modules are offered to handle:
•
ac or dc input power
•
low power (250 W) or high power (500 W) station requirements
A high power Power Supply Module (500 W) is used in a station with a high power
Power Amplifier Module (e.g., rated at 100 W or 75 W output power).
A low power Power Supply Module (250 W) is used in a station with a low power
Power Amplifier Module (e.g., rated at 40 W output power), or if the station is con-
figured as a Satellite Receiver.
ac Input Power
The 250 W models generates the +5.1 V and +14.2 V operating voltages for the sta-
tion modules.
The 500 W models generates the +5.1 V, +14.2 V, and +28 V operating voltages for
the station modules.
These modules have power factor correction and include a connection for battery
backup.
Table 1. Power Supply Module Models
Model
Supplied by
Input Voltage Range
Output
Voltages
Power Factor Correction
Stations with Low Power PA
DLN6624
ASTEC
85 to 264 Vac, 47 to
63 Hz
+5.1 V and
+14.2 V
Provided internally within
power supply module.
Stations with High Power PA
DLN6622
ASTEC
85 to 264 Vac, 47 to
63 Hz
+5.1 V,
+14.2 V,
and +28 V
Provided internally within
power supply module.