Configuration and Troubleshooting
2-78 Manual # 42-02-2P26
PMP Failed to Turn Off (246)
Traction Only. Normally closed Auxiliary contact for PM contact did not
pick at end of run. Fault-bypassed in Construction.
Correction:
1. Check PM aux contacts.
PMP Failed to Turn On (247)
Traction Only. Normally open Auxiliary contact for PM contact did not
drop out at beginning of run. Cannot be bypassed.
Correction:
1. Check PM aux contacts.
Positioning (9)
Car position has not been established. The car is reestablishing position.
Fault-bypassed in Construction/Inspection.
System Verifies:
- Car Flag Correction is active.
- Car is not on Inspection or construction operation.
- Car is on Automatic mode
Correction:
1. Car will move to reestablish position at a landing.
Processing Car Calls (291)
Generated while car is continuing to respond to registered car calls sub-
sequent to activation of capture mode (Pretest switch on SCE-CPU) or a
recall switch that is configured to answer existing car calls. Once calls are
satisfied, the elevator will recall and shut down awaiting test switch acti-
vation.
PTI Recall (100)
The car is recalling on emergency power operation. Fault-bypassed in
Construction/Inspection.
Correction:
1. View System IO > Programmed Inputs > PTI.
PTI Shutdown (101)
The car has stopped due to power loss. Fault-bypassed in Construction/
Inspection.
System Verifies:
- Power Transfer Data = PTI Shutdown
Correction:
1. View System IO > Programmed Inputs > PTI.
Quad Sensor Loss (Edge) (217)
Initiated by LS-EDGE-EL landing system. Indicates that one pair of quad
differential signals from the landing sensor to the controller has failed.
Fault-bypassed in Construction/Inspection.
Correction:
1. A hall effect sensor may have failed or the bias magnet is broken or
defective.
2. Contact MCE, may be defective LS-EDGE.
Quadrature Loss CH-B (230)
Initiated by LS-EDGE-EL landing system. Indicates that the controller is
not receiving the B channel of the quadrature signal stream from the
landing sensor. Fault-bypassed in Construction/Inspection.
Quadrature Offset CH-B (366)
Initiated by LS-EDGE-EL landing system. Indicates Channel B offset from
Channel A is not correct. Bypassed in Construction or Inspection Bypass
operation.
Random Calls Generator (18)
The random call generator has been activated. This generator is used to
exercise the elevator using random calls.
Correction: Check parameter setting.
Random Car Calls Gen (156)
The random car call generator has been activated. This generator is used
to exercise the elevator using random car calls.
Correction: Check parameter setting.
Table 2.15 Touch Screen Event Listings
Event
Description