Specifications
1-5
element
TM
Series
Specifications
This section lists specification and feature set information for traction installations.
• Environmental and Power Input
• Standardization and Code Compliance
• Operating Modes
• Operating Mode Definitions,
Table 1.1 Environmental and Power Input
Topic
Description
Enclosures
NEMA 1 standard, others available
Temperature
32 to 104° F, 0 to 40° C
Humidity
To 95% non-condensing
Altitude
To 10,000 feet (3000 meters), drive derating per manufacturer
Power Input
Power Input: 208 - 480 VAC, 50/60 Hz, 3 phase
Table 1.2 Standardization and Code Compliance
Topic
Description
Safety Codes (Fire Codes) - ASME A17.1/CSA B44 2016
- ASME A17.1/CSA B44 (2007 to 2013)
- ASME A17.1a/CSA B44S1 2005
- ASME A17.1/CSA B44 2004
- ASME A17.1/CSA B44 2000 W/Add
- ASME A17.1-1996 with addenda
- Massachusetts
- New York City
Special Needs
2010 ADA Standards
Electrical
NEC, U.S., CSA B44.1/ASME A17.5
Pollution
UL508C
Emissions
EN12016
Table 1.3 Operating Modes
Topic
Description
Simplex
Single car, integrated dispatching
Duplex
Two cars, both with integrated dispatching capability but with one car
assuming dispatching control for both
Call Response
Selective Collective automatic service
Automatic Operation
Passenger/normal
Test (contract speed operation without door opening)
Pretest (no hall call response, car recalls to capture floor after servicing
car calls)
Attended Operation
Independent service
In-car fire service (Fire Phase 2)
Inspection Operation
Cartop inspection
Car panel inspection
Hoistway access inspection
Machine room inspection