Serial Hall and Car Call Boards
1-47
element
TM
Series
Figure 1.3 CPI-2 Board Configuration
OMRON
CC24V
24V
COM
CC24V
COM
24V
IN
COM
SHLD
CAN L
CAN H
24V
NEXT BOARD
COM
RST
JP3
JP1
OFF
ON
LAMP
CAR CALL INDICATORS
USE CC24V POWER
LAMPS, BUZZERS,
ETC. USE
24V POWER
TO I/O PER
JOB PRINTS
GND
24
SW1
S1
TERMINATION
JP2
CAN
IN
CAN
OUT
MC-CPI-2
DOB DCL
BUZZER
JP2 CAN Termination. If
just one board is used,
this jumper must be
installed. If more than
one board is used, this
jumper must be installed
only on the LAST board.
See next figure.
CAN connection to Machine
Room through Traveler Cable
- including LS-QUTE Landing
System signals.
CAN connection to
Machine Room
through Traveler
Cable - including
LS-EDGE or
LS-RAIL Landing
System signals
SW1: See board addressing
on page 1-43.
To LS-EDGE
or LS-RAIL
Landing
System
Connect to CAN IN
on MC-CPI 2 board
JP3 set to 24 position for
active low inputs.