Configuration and Troubleshooting
2-48 Manual # 42-02-2P26
Table 2.10 HVI Connector Assignments
Connector
Assignment
Description
J3
UTL
Up Terminal Limit input, lighted when switch is closed
J3
USL1
Up Slow Limit 1 input, lighted when switch is closed
J3
USL2
Up Slow Limit 2 input, lighted when switch is closed
J3
DTL
Down Terminal Limit input, lighted when switch is closed
J3
DSL1
Down Slow Limit 1 input, lighted when switch is closed
J3
DSL2
Down Slow Limit 2 input, lighted when switch is closed
J3
UETS
Up Emergency Terminal Switch input, lighted when switch is closed
J3
DETS
Down Emergency Terminal Switch input, lighted when switch is closed
J4, MCE
2LS
2LS 110VAC input, MCE
J4, MCE
2LS
2LS 110VAC input, MCE
J4, MCE
PM
Motor Contactor power, MCE
J4, MCE
BR
Brake Contactor power, MCE
J5, MCE
2
2 bus, 110VAC input, MCE
J5, MCE
2
2 bus, 110VAC input, MCE
J5, MCE
2MV
2MV bus, 110VAC input, MCE
J5, MCE
1
Common, MCE
J5, MCE
1
Common, MCE
J6
USE/BR
Up Slow Enable output (pulls to ground when valve is activated), active when
power is on (110VAC)/BR is brake contactor output for traction application
J6
UFE/PM
Up Fast Enable output (pulls to ground when valve is activated), active when
power is on (110VAC/PM is motor contactor output for traction application
J6
DFE/EB1
Down Fast Enable output (pulls to ground when valve is activated), active when
power is on (110VAC)/EB1 is emergency brake output for traction
J6
DSE/EB2
Down Slow Enable output (pulls to ground when valve is activated), active
when power is on (110VAC)/EB2 is emergency brake output for traction
J6
RG
Rope Gripper (Not Used in hydraulic applications)
J7, MCE
2LS
2LS bus, 110VAC
J7, MCE
2MV
2MV bus, 110VAC
J7, MCE
GOV
Governor switch
J7, MCE
1
Common
J7, MCE
2
110VAC
J8, MCE
RG
Rope Gripper
J8, MCE
EB12
Emergency Brake
J8, MCE
EB1
Emergency Brake
J8, MCE
EB2
Emergency Brake
J8, MCE
EB3
Emergency Brake
J8, MCE
EB4
Emergency Brake
J8, MCE
ESC
Emergency stop switch bypass
J9
GOV
Governor, lighted when overspeed switch is closed
J9
SAFH
Safety string Hoistway, lighted when string is made (110VAC)
J9
SAFC
Safety string Car, lighted when string is made (110VAC)
J9
ESC
Emergency Switch Car, lighted when switch is closed (110VAC)
J9
2 2bus
110VAC
Содержание Nidec Element Series