Troubleshooting Reference
2-71
element
TM
Series
Heavy Load (47)
The car is loaded beyond the heavy load setting. Under this condition, a
moving car will ignore additional hall calls until the load is reduced by
passenger departure. Fault-bypassed in Construction.
System Verifies:
- Status of input
- Load Data = Load Heavy
Correction:
1. If in error, verify no input is programmed for Load Hvy.
2. Otherwise, verify status of input and input device.
3. Verify input wiring.
4. Verify System IO > Programmed Inputs > Load Hvy.
5. Calibrate load weigher.
Hoist. Access Construct (58)
The car is on construction operation and hoistway access. Cannot be
bypassed.
Correction:
1. Exit construction operation (
Construction Operation on page 1-8
Hoist. Access Inspection (62)
The car is on Inspection mode and hoistway access. Cannot be bypassed.
System Verifies:
- Mode of Operation = Inspection HA
Correction:
1. If in error, verify INA input.
In-Car Construct/Bypass (317)
Car panel inspection and construction operation are active and one or
both of the Car/Hoistway Door Bypass switches is in the Bypass position.
Cannot be bypassed.
System Verifies:
- ModeOfOperation = OpModeConstructionBPCP
Correction:
1. Exit construction operation (
Construction Operation on page 1-8
In-car Construction (57)
The car is operating in construction mode from the in-car controls.
In-Car Insp/Bypass (128)
Car Panel inspection is active and one or both of the Car/Hoistway Door
Bypass switches is in the Bypass position. Cannot be bypassed.
System Verifies:
- ModeofOperation = OpModeInspectionBPCP
Correction:
1. Turn off one or both of the Car/Hoistway Door Bypass switches.
In-Car Inspection (61)
The car is on Inspection mode and is being operated from the in-car
inspection station. Cannot be bypassed.
System Verifies:
- Mode of Operation = Inspection CP
Correction:
1. If in error, verify car panel inspection inputs.
Independent Mode (29)
The car is running on independent mode and will not accept hall calls.
Cannot be bypassed.
System Verifies:
Mode of Operation = Independent
Correction:
1. If in error, verify no input programmed IND SERV if IND SERV not
available.
2. Verify IND SERV input and initiating device wired per job prints.
Table 2.15 Touch Screen Event Listings