Installation
2-42 Manual # 42-02-2P24
MLT-SPD to DLY3
Assigns multi-step speed command to recog-
nition delay timer 1
-
None
mspd1-
mspd15
None
None
MLT-SPD to DLY4
Assigns multi-step speed command to recog-
nition delay timer 1
-
None
mspd1-
mspd15
None
None
C2 Logic Inputs
Log In 1 TB1-1
Terminal 1 Selection
-
-
DRIVE
ENABLE
DRIVE
ENABLE
Log In 2 TB1-2
Terminal 2 Selection
-
-
RUN
CON-
TACT
CFIRM
Log In 3 TB1-3
Terminal 3 Selection
-
-
FAULT
RESET
Log In 4 TB1-4
Terminal 4 Selection
-
-
UP/DWN
NO
FUNC-
TION
Log In 5 TB1-5
Terminal 5 Selection
-
-
S-CURVE
SEL 0
NO
FUNC-
TION
Log In 6 TB1-6
Terminal 6 Selection
-
-
STEP REF
B0
NO
FUNC-
TION
Log In 7 TB1-7
Terminal 7 Selection
-
-
STEP REF
B1
NO
FUNC-
TION
Log In 8 TB1-8
Terminal 8 Selection
-
-
STEP REF
B2
NO
FUNC-
TION
Log In 9 TB1-9
Terminal 9 Selection
-
-
EXTERN
FAULT 1
NO
FUNC-
TION
C3 Logic Outputs
Log Out 1 tb1-14
Terminal 14 Selection
-
-
READY
TO RUN
Log Out 2 tb1-15
Terminal 15 Selection
-
-
RUN COM-
MAND
RUN
COM-
MAND
Log Out 3 tb1-16
Terminal 16 Selection
-
-
MTR
OVER-
LOAD
SPEED
REG RLS
Log Out 4 tb1-17
Terminal 17 Selection
-
-
ENCODER
FAULT
RAMP
DOWN EN
Relay Coil 1
Relay 1 Function Selection
-
-
FAULT
READY
TO RUN
Relay Coil 2
Relay 2 Function Selection
-
-
SPEED
REG RLS
SPEED
REG RLS
Table 2.5 Magnetek AC Drive Table
#
Display
Parameter Description
Unit
Range
Defaults Factory
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...