![Motion Control Engineering Motion 4000 Скачать руководство пользователя страница 422](http://html1.mh-extra.com/html/motion-control-engineering/motion-4000/motion-4000_manual_1837882422.webp)
Appendix
A-10 Manual # 42-02-2P24
Configure C0
C1 User Switches
Spd Command Src Speed Command Source
-
Analog input
Multi-step
Serial
Multi-step Serial
Run Command Src Run Command Source
-
External TB
Serial
extern
External
TB1
Serial
Hi/Lo Gain Src
High / low gain change switch source
-
External TB 1
Serial
Internal
Internal
Speed Reg Type
Chooses speed regulator
-
Elev spd reg
Pi speed reg
Elev spd
reg
Motor Rotation
Allows user to reverse direction of motor rota-
tion
-
Forward
Reverse
Forward
Spd Ref Release
Determines when speed reference release is
asserted
-
Reg release
Brake picked
Reg
release
Cont Confirm Src
Enables external logic input for contactor con-
firmation.
-
None
External TB
None
Pre Torque Source Enables and determines the source of the pre
torque command
-
None
Analog input
Serial
None
Pre Torque Latch
Determines if analog pre-torque command is
latched
-
Not latched
Latched
Not
latched
PT torq Latch Clck Determines source of pre torque latch control
(if used)
-
External TB
Serial
External
tb
Fault Reset Src
Fault reset source
-
External TB
Serial
Automatic
External
tb
Overspd Test Src
Determines external logic source to trigger
overspeed test
-
External TB
Serial
External
tb
Brake Pick Src
If drive controls mechanical brake, determines
source of brake pick command
-
Internal
Serial
Internal
Brake Pick Cnfrm
Enables a logic input to use for brake pick con-
firmation
-
None
External TB
None
Brake Hold Src
If drive controls mechanical brake, determines
source of brake hold command
-
Internal
Serial
Internal
Ramped Stop Sel
Selects normal stop or torque ramp down stop -
None
Ramp on stop
None
Ramp Down En Src Determines the source that signals the torque
ramp down stop (if used)
-
External TB
Run logic
Serial
External
tb
Brk Pick Flt Ena
Brake pick fault enable
-
Enable
Disable
Disable
Brk Hold Flt Ena
Brake hold fault enable
-
Enable
Disable
Disable
Ext Torq Cmd Src
When Speed Reg Type = External Reg, sets
the source of the torque command
-
None
Serial
None
Table A.2 Magnetek AC Drive Table
#
Operator
Display
Parameter Description
Unit
Setting
Range
MCE
Defaults
Field Set
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...