Table 2.5 Magnetek AC Drive Table
#
Display
Parameter Description
Unit
Range
Defaults Factory
Adjust A0
A1 Drive
Contract Car Spd
Elevator Contract Speed
fpm
0 - 1500
400
Contract Mtr Spd
Motor Speed at elevator contract speed
rpm 50 - 3000
1130
Response
Speed regulator sensitivity. If set too high,
motor current and speed will be jittery. If too
small, the motor will be sluggish.
rad/
sec
1.0 - 20.0
10
10
Inertia
System inertia
sec
0.25 - 50.00
2.0
2.0
Inner Loop Xover
Inner speed loop crossover frequency (only
with Ereg speed regulator)
rad/
sec
0.1 - 20.0
2.0
2.0
Gain Reduce Mult
Speed regulator response percentage to use in
low gain Mode. 100% = no reduction.
%
10 - 100
100
100
Gain Chng Level
Speed level to change to low gain mode
(only with internal gain switch)
%
0 - 100.0
100
100
Tach Rate Gain
Compensates for rope resonance. Use only
after A1, Inertia, and A1, Response, have
been set correctly.
%
0 - 30.0
0
0
Spd Phase Margin Phase margin of speed regulator
(only with PI speed regulator)
o
45 - 90
80
80
Ramped Stop Time Time to ramp from rated torque to zero (only
with torque ramp down stop function)
sec
0 - 2.50
0.20
0.20
Contact Flt Time
Time before a contactor fault is declared
sec
0.10 - 5.00
0.50
0.80
Brake Pick Time
Time before a brake pick fault is declared
sec
0 - 5.00
1.00
0.0
Brake Hold Time
Time before a brake hold fault is declared
sec
0 - 5.00
0.20
0.20
Overspeed Level
Threshold for detection of overspeed fault
%
100.0 - 150.0 115.0
115.0
Overspeed Time
Time before an overspeed fault is declared
sec
0 - 9.99
1.00
1.00
Overspeed Mult
Multiplier for overspeed test (U4)
%
100 - 150
125
125
Encoder Pulses
Encoder counts per revolution
ppr
600 - 10000
1024
Spd Dev Lo Level
Range around the speed reference for speed
deviation low logic output
%
00.1 - 10.0
10
10
Spd Dev Time
Time before speed deviation low logic output
is true
sec
0 - 9.99
0.5
0.5
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...