User Interface
4-34 Manual # 42-02-2P24
UPI
Up Input (Attendant Service) - Used by an attendant during attendant service operation to
establish a direction preference. Pushing the “UP” button in the car will activate this input,
causing the computer to generate SUA (up direction preference) and DSHT (door shorten-
ing) to close the doors.
WLD
Emergency Dispatch Input - Causes Wild operation (emergency dispatching) to be disabled.
Created to allow building personnel or elevator maintenance personnel to disable emer-
gency dispatching on one or more cars in a multi-car system. For example, if the dispatcher
of an 8-car group were to fail, the building may only want 3 cars to run on “wild operation”.
The remaining 5 cars would be inhibited from running on “wild operation” by activating the
WLD input for each.
WPIA - WPIH
Bracelet Security (Wandering Patient Security) inputs. These inputs work in conjunction
with the WPIA Landing/Side (opening) option in the Extra Features menu. Landing and side
options must be set for each WPIx input programmed. When a WPIx input is activated, hall
calls to the programmed landing and side associated with the input will be disabled. If the
elevator is already located at that landing with the doors open, it will be prevented from
leaving that landing and will shut down. (AKA Infant Abduction Security)
Table 4.6 Spare Inputs Menu Options
Spare Inputs Menu Options
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...