![Motion Control Engineering Motion 4000 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/motion-control-engineering/motion-4000/motion-4000_manual_1837882076.webp)
Installation
2-38 Manual # 42-02-2P24
Notch Filter Frq
Notch Filter Center Frequency
Hz
5 - 60
20
20
Notch Filt Depth
Notch filter maximum attenuation
%
0 - 100
0
0
MSPD Delay 1-4
Recognition time delay for a defined multistep
speed command
sec
0.00 - 10.0
0.00
0.00
A2 S-Curves
Accel Rate 0
Acceleration rate #0
ft/s
2
0 - 7.99
3.00
0.00
Decel Rate 0
Deceleration rate #0
ft/s
2
0 - 7.99
3.00
0.00
Accel Jerk in 0
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Jerk out 0
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk in 0
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk out 0
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Rate 1
Acceleration rate #1
ft/s
2
0 - 7.99
3.00
0.0
Decel Rate 1
Deceleration rate #1
ft/s
2
0 - 7.99
3.00
0.0
Accel Jerk in 1
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Jerk out 1
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk in 1
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk out 1
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Rate 2
Acceleration rate #2
ft/s
2
0 - 7.99
3.00
0.00
Decel Rate 2
Deceleration rate #2
ft/s
2
0 - 7.99
3.00
0.00
Accel Jerk in 2
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Jerk out 2
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk in 2
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk out 2
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Rate 3
Acceleration rate #3
ft/s
2
0 - 7.99
3.00
0.00
Decel Rate 3
Deceleration rate #3
ft/s
2
0 - 7.99
3.00
0.00
Accel Jerk in 3
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Accel Jerk out 3
Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk in 3
Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 29.9
8.0
0.0
Decel Jerk out 3
Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 29.9
8.0
0.0
Table 2.5 Magnetek AC Drive Table
#
Display
Parameter Description
Unit
Range
Defaults Factory
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...