TECHNICAL DATA
GENERATOR
TS 400 YS
Three-phase generation
16 kVA / 400 V / 23.1 A
Single-phase generation
10 kVA / 230 V / 43.5 A
Single-phase generation
5 kVA / 110 V / 45.5 A
Single-phase generation
5 kVA / 48 V / 104 A
Frequency
50 Hz
ALTERNATOR
self-excited, self-regulated, brushless
Type
Three-phase, asynchronous
Insulating class
H
ENGINE
Mark / Model
YANMAR 4TNV88 (STAGE V)
Type / Cooling system
Diesel 4-Stroke / Air
Cylinders / Displacement
4 / 2190 cm³
Net output (stand-by)
18 kW (24.5 HP)
Speed
1500 rpm
Fuel consumption (welder 60%)
3.15 l/h
Engine oil capacity
7.4 l
Starter
Electric
GENERAL SPECIFICATION
Tank capacity
60 l
Running time (welder 60%)
19 h
Protection
IP 23
*
Dimensions max. on base Lxlxh (mm)
1720x850x1128
*Weight
750 Kg
Measured acoustic power LwA (pressure LpA)
94 dB(A) (69 dB(A) @ 7 m)
Guaranteed acoustic power LwA (pressure LpA)
95 dB(A) (70 dB(A) @ 7 m)
*
Dimensions and weight are inclusive of all parts without wheels and towbar
2000 / 14 / CE
REV
.0-10/19
CAUTION
RUNNING-IN
During the first 50 hours of operation, do not use more than 60% of the maximum output power of the unit and check the oil
level frequently, in any case please stick to the rules given in the engine use manual.
!
POWER
Declared power according to
ISO 3046-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION
:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(L
W
A)
- Measure Unit dB(A)
:
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A)
:
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
W
A)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE
:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE