11
TriStar MPPT-600V-TR Operator's Manual
10
Getting Started
Getting Started
2.0
2.1 Overview
Thank you for selecting the TS-MPPT-600V-TR solar charge controller. Both models are
specialized components designed for use in grid-tie / off-grid systems. These products feature a
transfer switch which allows the user to toggle connections between a grid-tie inverter and
battery bank storage. The diagram below shows the basic dual-mode functionality of the
product.
SOLAR
ARRAY
Input (+) and
(-) Wires
TS-600V-MPPT-TR
Battery
Disconnect
Main Input
Disconnect
Battery
Bank
Grid-tie
Inverter
Transfer
Switch
GFPD
PV and battery
(+) and (-)
connections
PV and battery
(+) and (-)
connections
The TS-MPPT-600V-TR with TrakStar
TM
MPPT Technology is an advanced maximum power point
tracking solar battery charger. The controller features a smart tracking algorithm that finds and
maintains operation at the solar array peak power point, maximizing energy harvest.
The TS-MPPT-600V-TR battery charging process has been optimized for long battery life and
improved system performance. Self-diagnostics and electronic error protections prevent damage
when installation mistakes or system faults occur. The controller also features eight (8) adjustable
settings switches, several communication ports, and terminals for remote battery temperature
and voltage measurement.
Please take the time to read this operator’s manual and become familiar with the controller. This
will help you make full use of the many advantages the TS-MPPT-600V-TR can provide for your
PV system.
2.2 Regulatory Information
NOTE:
This section contains important information for safety and
regulatory requirements.
The TS-MPPT-600V-TR controller should be installed by a qualified technician according to the
electrical rules of the country in which the product will be installed.
TS-MPPT-600V-TR controllers comply with the following EMC standards:
• Immunity: EN61000-6-2: 2005
• Emissions: EN55022:2 2007 with A1 and A3 Class B1
• Safety: EN60335-1 and EN60335-2-29 (battery chargers)
A means shall be provided to ensure all pole disconnection from the power supply. This discon-
nection shall be incorporated in the fixed wiring.
Using the TS-MPPT-600V-TR grounding terminal (in the wiring compartment), a permanent and
reliable means for grounding shall be provided. The clamping of the earthing shall be secured
against accidental loosening.
The entry openings to the TS-MPPT-600V-TR wiring compartment shall be protected with conduit
or with a bushing.
FCC requirements:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation. Changes
or modifications not expressly approved by Morningstar for compliance could void the user’s
authority to operate the equipment.