79
TriStar MPPT-600V-TR Operator's Manual
78
Warranty and Policies
10.0 Appen-
dix
10.0 Appen-
dix
WARRANTY CLAIM PROCEDURE
1. Before proceeding, please refer to product manual, including Troubleshooting section.
2. Contacting your authorized Morningstar distributor or dealer from whom you purchased the unit is
the first step in the warranty process. Local dealers can often address warranty issues quickly.
3. If supplier is unable to address the issue, please contact Morningstar by e-mail (support@morning-
starcorp.com) with:
(A) purchase location -- business or company name
(B) full model and serial numbers (SN is 8-digits on unit
bar label)
(C) failure behavior, including LED indications
(D) array configuration, panel Pmax, Voc, Vmp, Isc, and
nominal battery voltage; these specifications are
needed to receive assistance.
(E) multi-meter available (for field troubleshooting)
4. After warranty replacement has been approved and new unit(s) received, please return failed
unit(s) using pre-paid shipping label, and follow any product specific instructions if requested by
Morningstar Warranty Dept.
5. If instructed by Morningstar, after warranty replacement shipment has been received, return of
failed unit(s) is
required before further warranty replacements can be
considered for the original or future cases.
NOTE: Please do not return units without an RMA or case number. Doing so will increase the
time required to resolve your claim.
9.0
Technical Specifications
REFER TO THE INCLUDED GFPD-600V OPERATOR'S MANUAL FOR THAT PRODUCT'S
SPECIFICATIONS
Electrical
TS-MPPT-60-600V-48-DB-
TR
TS-MPPT-60-600V-48-DB-
TR-GFPD
Nominal System Voltage
48 volts
48 volts
Maximum Battery Current
60 amps 60 amps
(63A breaker included)
Maximum Solar Input Voltage
600 volts dc 600 volts dc
Battery Operating Voltage Range
16 - 72 volts dc
16 - 72 volts dc
Maximum Operating Input Current
15 amps
15 amps
Nominal Maximum Input Power*
3200 watts
3200 watts
Voltage Accuracy
≤ 0.1 % ± 100 mV
≤ 0.1 % ± 100 mV
Self consumption (tare loss)
2-3.5 watts 2-3.5 watts
Transient Surge Protection
4500 watts / port 4500 watts / port
*These power levels refer to the maximum wattage the TS-MPPT-60-600V-48 can process.
Higher power
arrays
can be used without damaging the controller.
Battery Charging
Charging algorithm
4 - stage
Charging
stages Bulk,
Absorption,
Float,
Equalize
Temperature compensation coefficient
-5 mV / °C / cell (25 °C ref.)
Temperature compensation range (RTS connected)
-30 °C to +80 °C
Temperature compensated set-points:
Absorption, Float, Equalize, HVD
Charging Set-points (48 volt systems):
Settings
Switches
Battery
Type
Absorp.
Stage
Float
Stage
Equalize
Stage
Absorp.
Time
Equalize
Time
Equalize
Timeout
Equalize
Interval
sw: 4-5-6
Volts
Volts
Volts
Minutes Minutes Minutes
Days
off-off-off
1 - Sealed*
56.00
54.80
150
off-off-on
2 - Sealed*
56.60
54.80
57.60
150
60
120
28
off-on-off
3 - Sealed*
57.20
54.80
58.40
150
60
120
28
off-on-on 4 - AGM/Flooded
57.60
54.80
60.40
180
120
180
28
on-off-off
5 - Flooded
58.40
54.00
61.20
180
120
180
28
on-off-on
6 - Flooded
58.80
54.00
61.60
180
180
240
28
on-on-off
7 - L-16
61.60
53.60
64.00
180
180
240
14
on-on-on
8 - Custom
Custom
Custom
Custom
Custom
Custom
Custom
Custom
* “Sealed” battery type includes gel and AGM batteries