M O R N I N G S T A R C O R P O R A T I O N
2
I M P O R T A N T S A F E T Y I N S T R U C T I O N S
WARNING:
RISK OF ELECTRICAL SHOCK.
NO POWER OR ACCESSORY TERMINALS ARE ELECTRICALLY
ISOLATED FROM DC INPUT, AND MAY BE ENERGIZED WITH HAZARD-
OUS SOLAR VOLTAGE. UNDER CERTAIN FAULT CONDITIONS, BATTERY
COULD BECOME OVER-CHARGED. TEST BETWEEN ALL TERMINALS AND
GROUND BEFORE TOUCHING.
• External solar and battery disconnects are required.
• Disconnect all sources of power to the controller before installing or adjusting
the TriStar-PWM.
• There are no fuses or disconnects inside the TriStar-PWM Do not attempt to
repair.
Informations de Sécurité
•
Lisez toutes les instructions et les avertissements figurant dans le manuel
avant de commencer l’installation.
• Le TriStar-PWM ne contient aucune pièce réparable par l’utilisateur. Ne dé-
montez pas ni ne tentez de réparer le contrôleur.
AVERTISSEMENT:
RISQUE DE CHOC ÉLECTRIQUE. NON
ALIMENTATION OU AUX BORNES D’ACCESSOIRES SONT ISOLÉS
ÉLECTRIQUEMENT DE L’ENTRÉE DE C.C ET DOIT ÊTRE ALIMENTÉS À UNE
TENSION DANGEREUSE SOLAIRE. SOUS CERTAINES CONDITIONS DE
DÉFAILLANCE, LA BATTERIE POURRAIT DEVENIR TROP CHARGÉE. TEST
ENTRE TOUTES LES BORNES ET LA MASSE AVANT DE TOUCHER.
• External solaire et la batterie se déconnecte sont nécessaires.
• Déconnectez toutes les sources d’alimentation du contrôleur avant d’installer
ou de régler le TriStar-PWM.
• Le TriStar MPPT ne contient aucun fusible ou interrupteur. Ne tentez pas de
réparer.
• Installez des fusibles/coupe-circuits externes selon le besoin.
Installation Safety Precautions
WARNING:
This unit is not provided with a GFDI
device. This charge controller must be used with an external GFDI
device as required by the Article 690 of the National Electrical Code for the
installation location.
• Mount the TriStar-PWM indoors. Prevent exposure to the elements and do not
allow water to enter the controller.
• Install the TriStar-PWM in a location that prevents casual contact. The TriStar-
PWM heatsink can become very hot during operation.
• Use insulated tools when working with batteries.
• Avoid wearing jewelry during installation.
. . .
• The battery bank must be comprised of batteries of same type, make, and
age.
• IEC 62109 certified for use in negative ground or floating systems only
• Do not smoke near the battery bank.
• Power connections must remain tight to avoid excessive heating from a loose
connection.
• Use properly sized conductors and circuit interrupters.
•
The grounding terminal is located in the wiring compartment and is identifie
d
by the symbol below:
Ground Symbol
• This charge controller is to be connected to DC circuits only. These DC
connections are identified by the symbol below:
Direct Current Symbol
The TriStar-PWM controller must be installed by a qualified technician in
accordance with the electrical regulations of the country where the product is
installed.
A means of disconnecting all power supply poles must be provided.
These disconnects must be incorpo
rated in the fixed wiring.
A permanent
,
reliable earth ground must be established with connection to the
TriStar-PWM wiring compartment ground terminal.
The grounding conductor must be secured against any accidental detachment.
The knock-outs in the TriStar-PWM wiring compartment must protect wires with
conduit or rubber rings.
Précautions de Sécurité D’installation
AVERTISSEMENT:
L’appareil n’est pas fourni avec
un dispositif GFDI. Ce contrôleur de charge doit être utilisé avec un
dispositif GFDI externe tel que requis par l’Article 690 du Code électrique
national de l’emplacement de l’installation.
• Montez le TriStar-PWM à l’intérieur. Empêchez l’exposition aux éléments et la
pénétration d’eau dans le contrôleur.
• Installez le MPPT ProStar dans un endroit qui empêche le contact occasion-
nel. Le dissipateur de chaleur TriStar-PWM peut devenir très chaud pendant